beautypg.com

Atec Narda-SRM-3006 User Manual

Page 14

background image

Single-axis antenna (H-field) 3551/02

Frequency range

9 kHz to 300 MHz
The correction factors determined individually during calibration are stored in an EEPROM and
are applied automatically when used in conjunction with the SRM basic unit.

Antenna type

H-field

Sensor type

Single axis active magnetic loop

Dynamic range

a

0.4 µA/m to 71 mA/m

CW damage level

> 2.65 A/m above 1 MHz

Intrinsic noise display in conjunction with
the SRM basic unit

b

0.12 µA/m for each frequency > 10 MHz with 1 kHz resolution bandwidth RBW

Measurement range limit
(for single CW signal)

b

100 mA/m

RF connector

N connector, 50 Ω

UNCERTAINTY

Frequency range

Single-axis measurement

Extended measurement uncertainty

c

(in conjunction with SRM basic unit and
1.5 m cable)

0.1 - 300 MHz

2.0 dB

Calibration uncertainty

< 1.2 dB

GENERAL SPECIFICATION
Operating temperature range

-10 °C to 50 °C (same as SRM basic unit)
Storage

1K3 (IEC 60721-3) extended to -10 °C to +50 °C

Transport

2K4 (IEC 60721-3)

Climatic

Operating

7K2 (IEC 60721-3)

Storage

1M3 (IEC 60721-3)

Transport

2M3 (IEC 60721-3)

Mechanical

Operating

7M3 (IEC 60721-3)

ESD and EMC

EN 61326:2006

Safety

EN 61010-1:2004

Compliance

EU Guidelines

2003/11/EG 06.02.2003 (PBDE and OBDE)
2002/95/EG 27.01.2003 (RoHS)
2002/96/EG 27.01.2003 (WEEE)

CE (European Community)

Yes

Air humidity

< 29 g/m³ (< 93 % at +30 °C)

Weight 450

g

Dimensions

460 mm length; 43 x 100 mm antenna head dimension

Calibration

183 reference points
The SRM interpolates between reference points

Recommended calibration interval

24 months

Country of origin

Germany

a Typical measurement dynamic range for 10 dB signal to noise radio (RBW = 1 kHz); for frequencies > 10 MHz
b Typical values
c Typical value, with k = 2 (k = extrapolation or correction factor for determining the assessment value); +15 °C to +30 °C

NSTS 1109- ME-E0272C-0.00

14 / 16

Subject to change without notice