Single axis antenna (E-field) 3531/03
Frequency range
9 kHz to 300 MHz
The correction factors determined individually during calibration are stored in an EEPROM and
are applied automatically when used in conjunction with the SRM basic unit.
Antenna type
E-field
Sensor type
Single axis active broadband dipole
Dynamic range
a
70 µV/m to 16 V/m for 300 kHz to 10 MHz
70 µV/m to 36 V/m for > 10 MHz to 300 MHz
CW damage level
> 1000 V/m
Intrinsic noise display in conjunction with
the SRM basic unit
b
20 µV/m in the range from 1 MHz to 300 MHz with 1 kHz resolution bandwidth (RBW)
Measurement range limit
(for single CW signal)
b
50 V/m
RF connector
N connector, 50 Ω
UNCERTAINTY
Frequency range
Single-axis measurement
Extended measurement uncertainty
c,
(in conjunction with SRM basic unit and
1.5 m cable)
0.1 - 300 MHz
2.0 dB
Calibration uncertainty
< 1.2 dB
GENERAL SPECIFICATIONS
Operating temperature range
-10 °C to 50 °C (same as SRM basic unit)
Storage
1K3 (IEC 60721-3) extended to -10 °C to +50 °C
Transport
2K4 (IEC 60721-3)
Climatic
Operating
7K2 (IEC 60721-3)
Storage
1M3 (IEC 60721-3)
Transport
2M3 (IEC 60721-3)
Mechanical
Operating
7M3 (IEC 60721-3)
ESD and EMC
EN 61326:2006
Safety
EN 61010-1:2004
Compliance
EU Guidelines
2003/11/EG 06.02.2003 (PBDE and OBDE)
2002/95/EG 27.01.2003 (RoHS)
2002/96/EG 27.01.2003 (WEEE)
CE (European Community)
Yes
Air humidity
< 29 g/m³ (< 93 % to +30 °C)
Weight 550
g
Dimensions
460 mm length; 135 x 90 mm antenna head dimension
Calibration
183 reference points
The SRM applies linear interpolation between reference points.
Recommended calibration interval
24 months
Country of origin
Germany
a Typical measurement dynamic range for 10 dB signal to noise radio (RBW = 1 kHz)
b Typical values
c Typical value, with k = 2 (k = extrapolation or correction factor for determining the assessment value); +15 °C to +30 °C