PRODUCT INFORMATION SINGLE-AXIS ANTENNAS
Single-axis antenna (E-field) 3531 / 01
Frequency range
27 MHz to 3 GHz
Antenna type
E-Field
Sensor type
Single axis passive wide band dipole
Dynamic range
a
60 µV/m to 160 V/m
CW damage level
> 300 V/m or 25 m/Wcm²
Intrinsic noise display in conjunction with
the SRM basic unit
b,
20 µV/m from 100 MHz to 2.2 GHz with 1 kHz RBW
Measurement range limit
b
160 V/m
RF connector
N connector, 50 Ω
UNCERTAINTY
Frequency range
Single-axis measurement
26 - 300 MHz
2.1 dB
> 301 - 433 MHz
2.4 dB
> 434 - 1600 MHz
2.2 dB
Extended measurement uncertainty
d
(in conjunction with SRM basic unit and
1.5 m RF cable)
> 1601 - 3000 MHz
1.9 dB
Calibration uncertainty
< 1.5 dB
GENERAL SPECIFICATIONS
Operating temperature range
-10 °C to 50 °C (same as SRM basic unit)
Storage
1K3 (IEC 60721-3) extended to -10°C to +50°C
Transport
2K4 (IEC 60721-3)
Climatic
Operating
7K2 (IEC 60721-3)
Storage
1M3 (IEC 60721-3)
Transport
2M3 (IEC 60721-3)
Mechanical
Operating
7M3 (IEC 60721-3)
ESD and EMC
EN 61326:2006
Safety
EN 61010-1:2004
Compliance
EU Guidelines
2003/11/EG 06.02.2003 (PBDE and OBDE)
2002/95/EG 27.01.2003 (RoHS)
2002/96/EG 27.01.2003 (WEEE)
CE (European Community)
Yes
Air humidity
< 29 g/m³ (< 93 % to +30 °C)
Weight 450
g
Dimensions
460 mm length; 135 x 90 mm antenna head dimensions
Calibration
24 reference points
Recommended calibration interval
24 months
Country of origin
Germany
a Typical measurement dynamic range for 10 dB signal to noise ratio (RBW = 1 kHz); 100 MHz – 2.2 GHz
b Typical values
c Typical value, with k = 2 (k = extrapolation or correction factor for determining the assessment value); +15 °C to +30 °C
NSTS 1109- ME-E0272C-0.00
12 / 16
Subject to change without notice