Option 002 built-in tracking generator
2
(8560E only)
Frequency specifications
Frequency range
300 kHz to 2.9 GHz
Accuracy
After peaking
±(frequency reference
accuracy x tuned frequency
+5% x span + 295 Hz)
Tracking drift (nominal)
Usable in 1 kHz RBW
after 5-minute warm-up,
usable in 300 Hz RBW
after 30-minute warm-up.
Minimum RBW
300 Hz
3
Amplitude specifications
Output level
–10 dBm to +1 dBm
(10 dBm to +2.8 dBm typical)
Resolution
0.1 dB
Accuracy
Vernier
±0.20 dB/dB, ±0.5 dBm
max (25 °C ±10 °C)
Absolute
±0.75 dB
Level flatness
±2.0 dB
Effective source match
1.92:1 (nominal)
Total absolute accuracy
±3.25 dB
10
Option 001 second IF output, Agilent 8560 series
(All values are nominal)
3 dB bandwidth
8560E
8561E
8562E
8563E
8564E,8565E
NF
conversion gain
30 Hz to 2.9 GHz1
>25 MHz
>25 MHz
>25 dB
>25 MHz
>25 MHz
24 dB
25 dB
20 dB
25 dB
28 dB
1.2 dB
–6.5 dB
–1.2 dB
–1.2 dB
–1.2 dB
2.9 GHz to 6.5 GHz
>30 MHz
>30 MHz
>30 MHz
>30 MHz
26 dB
22 dB
22 dB
23 dB
–1 dB
–3 dB
–1 dB
–1 dB
6.5 GHz to 13.2 GHz
>37 MHz
>37 MHz
>37 MHz
26 dB
26 dB
28 dB
–5.7 dB
–5.7 dB
–5.7 dB
13.2 GHz to 22 GHz
>45 MHz
>45 MHz
30 dB
32 dB
–8 dB
–8 dB
22 GHz to 26.8 GHz
>45 MHz
>45 MHz
32 dB
35 dB
–8 dB
–8 dB
26.8 GHz to 31.15 GHz
>25 MHz
28 dB
–9 dB
31.15 GHz to 40 GHz
>25 MHz
38 dB
–19 dB
40 GHz to 50 GHz
>25 MHz
42 dB
–23 dB
Options
1. DC coupled for frequencies below 100 kHz. Option 006 required for operation below 9 kHz in 8563E, 8564E, 8565E.
2. Option 002 deletes millimeter external mixer capability (Second IF input is deleted)
3. Tracking generator not usable with resolution bandwidths
≤
100 Hz