Option 002 built-in tracking generator

2

(8560E only)

Frequency specifications

Frequency range

300 kHz to 2.9 GHz

Accuracy

After peaking

±(frequency reference
accuracy x tuned frequency
+5% x span + 295 Hz)

Tracking drift (nominal)

Usable in 1 kHz RBW
after 5-minute warm-up,
usable in 300 Hz RBW
after 30-minute warm-up.

Minimum RBW

300 Hz

3

Amplitude specifications

Output level

–10 dBm to +1 dBm

(10 dBm to +2.8 dBm typical)

Resolution

0.1 dB

Accuracy
Vernier

±0.20 dB/dB, ±0.5 dBm
max (25 °C ±10 °C)

Absolute

±0.75 dB

Level flatness

±2.0 dB

Effective source match

1.92:1 (nominal)

Total absolute accuracy

±3.25 dB

10

Option 001 second IF output, Agilent 8560 series

(All values are nominal)

3 dB bandwidth

8560E

8561E

8562E

8563E

8564E,8565E

NF
conversion gain

30 Hz to 2.9 GHz1

>25 MHz

>25 MHz

>25 dB

>25 MHz

>25 MHz

24 dB

25 dB

20 dB

25 dB

28 dB

1.2 dB

–6.5 dB

–1.2 dB

–1.2 dB

–1.2 dB

2.9 GHz to 6.5 GHz

>30 MHz

>30 MHz

>30 MHz

>30 MHz

26 dB

22 dB

22 dB

23 dB

–1 dB

–3 dB

–1 dB

–1 dB

6.5 GHz to 13.2 GHz

>37 MHz

>37 MHz

>37 MHz

26 dB

26 dB

28 dB

–5.7 dB

–5.7 dB

–5.7 dB

13.2 GHz to 22 GHz

>45 MHz

>45 MHz

30 dB

32 dB

–8 dB

–8 dB

22 GHz to 26.8 GHz

>45 MHz

>45 MHz

32 dB

35 dB

–8 dB

–8 dB

26.8 GHz to 31.15 GHz

>25 MHz
28 dB
–9 dB

31.15 GHz to 40 GHz

>25 MHz
38 dB
–19 dB

40 GHz to 50 GHz

>25 MHz
42 dB
–23 dB

Options

1. DC coupled for frequencies below 100 kHz. Option 006 required for operation below 9 kHz in 8563E, 8564E, 8565E.
2. Option 002 deletes millimeter external mixer capability (Second IF input is deleted)
3. Tracking generator not usable with resolution bandwidths

100 Hz