Power meter specifications continued – Atec Anritsu-MA2445A User Manual

Page 4

background image

4

ML2430A Series

ML2480A Series

ML2490A Series

Comments

ML2437A

ML2438A

ML2487A

ML2488A

ML2495A

ML2496A

Operation

2

2 (CW or Pulse/Modulated measurement modes)

Measurement Display-

Readout (Numerical)

Power vs. Time graphic of readout data

or Profile of Peak power for analysis of

repetitive pulse or transient waveforms

2 (Pulse/Modulated measurement mode)

Measurement Display-

Profile (Graph)

Single channel power sweep or frequency sweep

Source sweep

±5 dB range CW (Readout mode) only

Peaking meter

Dynamic range covered by five overlapping

amplifier ranges, R1, R2, R3, R4 and R5
Universal Sensor MA2481/82D ranges 1 to 6

Pulse modulated mode:

Dynamic range covered by three overlapping amplifier ranges, R7, R8 and R9
CW mode:

Dynamic range covered by five overlapping amplifier ranges, R1, R2, R3, R4 and R5
Universal Sensor MA2481/82D ranges 1 to 6

Amplifier Range

Auto or Manual

(current range or selectable 1 through 5)

Automatic or manual. When in manual clear indication given to user

(display and GPIB) of fault conditions (under or over-range)

Range Hold

Features

(summary)

0.1 to 0.001 dB
Linear power units, 3 to 6 digit, 1 to 3 digits

selectable to right of decimal nW to W;
Voltage, 1 to 2 digits selectable to right

of decimal

0.1 to 0.001 dB

Display resolution in

Readout mode

0.01 dB

Display resolution in

Profile mode

Profile and P vs. T modes:

200 pixels display resolution
For a 1 ms Profile window, cursor resolution

on the display is 5 µs

16 ns

Pulse/Modulated mode
15 µs

CW Mode

1 ns (RSS mode)

16 ns (non RSS mode)

Pulse/Modulated mode
15 µs

CW Mode

Time measurement

resolution

Hold, Max, Min

Measurement hold

Average, Min, Max

Average, Min, Max, Peak, Crest, PAE (Power Added Efficiency)

Measurements

PDF, CDF, CCDF

Power statistics

0.00 to 20.00V nominal

Voltage

measurement range

Watt, %, Volts

Display units (Lin)

Display units (Log)

dBm, dB, dBµV, dBmV, dBr

dBm, dBW, dB, dBµV, dBmV

–199.99 to +199.99 dB

Display range

1

Four Independently set Gates or eight repeated Gates
One Fence per Measurement gate
Gate measurement supports Average, Peak, Crest, Max and Min

Measurement Gates

2

Four Markers and One Delta Marker, Marker to Max/Min, Pulse Rise/Fall-time,

Pulse Width, Off Period, Pulse Repetition Interval
Rise Fall/Search Parameter Variable %
Reference: Max Marker or Gate Power Level

Markers

Fixed value high and low limits with audible,

rear panel TTL output, and/or visible

Pass/Fail alarm indication
Failure indication can latch for

transient failure detection

Simple pass/fail for CW
Complex limits for pulsed and TDMA systems
30 Limits Stores available on the instrument

Limit lines

–199.99 to +199.99 dB (Fixed value or frequency dependent table)

Offset range

Power Meter Specifications continued