Atec Agilent-60504B User Manual
Page 4
5
Table 60504-1 Specifications and Supplemental Characteristics (continued)
Current Slew Rate:*
Rate #
120 A Range Step
12 A Range Step
Transition Time
1
2 A/ms
0.2 A/s
8.0 ms
2
5 A/ms
0.5 A/s
3.2 ms
3
10 A/ms
1 A/ms
1.6 ms
4
20 A/ms
2 A/ms
800
µ
s
5
50 A/ms
5 A/ms
320
µ
s
6
100 A/ms
10 A/ms
160
µ
s
7
0.2 A/
µ
s
20 A/ms
80
µ
s
8
0.5 A/
µ
s
50 A/ms
32
µ
s
9
1 A/
µ
s
100 A/ms
16
µ
s
10
2 A/
µ
s
0.2 A/
µ
s
12
µ
s
11
5 A/
µ
s
0.5 A/
µ
s
12
µ
s
12
10 A/
µ
s
1 A/
µ
s
12
µ
s
*AC performance specified from 3 to 60 V.
Voltage Slew Rate:
Rate #
Voltage Range Step
Transition Time*
1
1 V/ms
8.0 ms
2
2.5 V/ms
3.2 ms
3
5 V/ms
1.6 ms
4
10 V/ms
800
µ
s
5
25 V/ms
320
µ
s
6
50 V/ms
160
µ
s
7
0.1 V/
µ
s
85
µ
s
8
0.25 V/
µ
s
85
µ
S
9
0.5 V/
µ
s
85
µ
S
*Transition time based on low capacitance current source.
Resistance Slew Rate
(0.5
Ω
range): Uses the value programmed for voltage slew rate.
Resistance Slew Rate
(500
Ω
and 5 k
Ω
ranges): Uses the value programmed for current slew rate.
Transient Current Overshoot (When programmed from 0A):
Range
Transient Current Level
Current Slew Rate
Overshoot*
120 A
24-120 A
All slew rates
0
6 A
0.5 A/
µ
s and 10 A/
µ
s
6%
6 A
2 A/
µ
s
3%
6 A
1 A/
µ
s
1%
6 A
0.2 A/ms to 0.5 A/
µ
s
0
12 A
2 A/ms to 2 A/
µ
s
0
12 A
5 A/ms and 10 A/
µ
s
2%