Atec Agilent-60504B User Manual
Page 3
4
Table 60504-1 Specifications and Supplemental Characteristics (continued)
External Analog Programming 0 to 10 V (dc or ac):
Bandwidth:
10 kHz (3 db frequency)
Accuracy:
± 4% ± 200 mA (0 to 12 A range)
± 4% ± 400 mA (0 to 120 A range)
± 0.8% ± 200 mV (0 to 60 V range)
Temperature Coefficient:
100 ppm/
°
C ± 12 mA/
°
C (current ranges)
100 ppm/
°
C ± 1 mV/
°
C (voltage range)
External Current Monitor (0 to 10 V):
Accuracy:
± 0.4% ± 170 mA (referenced to analog common)
Temperature Coefficient:
100 ppm/
°
C ± l0 mA/
°
C
External Voltage Monitor
(0 to 10 V):
Accuracy:
± 0.4% ± 60 mV (referenced to analog common)
Temperature Coefficient:
100
ppm/
°
C ± 2 mV/
°
C
Remote Sensing:
5 Vdc maximum between sense and input binding posts
Maximum Input Levels:
Current:
122.4 A (programmable to lower limits)
Voltage:
75 V
Minimum Operating Voltage:
2 V (derated to 0 V at 0 A)
PARD (20 Hz to 10 MHz noise):
Current:
6 mA rms/60 mA p-p
Voltage:
8 mV rms
DC Isolation Voltage:
± 240 Vdc between + or - input binding post and chassis ground
Digital Inputs:
Vlo:
0.9 V maximum at Ilo = -1 mA
Vhi
3.15 V minimum (pull-up resistor on input)
Digital Outputs:
V
lo:
0.72 V maximum at Ilo = 1 mA
Vhi:
4.4 V minimum at Ilo - 20
µ
A
SUPPLEMENTAL CHARACTERISTICS
Programmable Slew Rate (For any given input transition, the time required will be either the total slew time or a minimum
transition time, whichever is longer. The minimum transition time increases when operating with input currents under 2 A.
The following are typical values; ± 25% tolerance):