beautypg.com

Atec Agilent-60504B User Manual

Page 2

background image

3

Table 60504-1 Specifications and Supplemental Characteristics (continued)

Transient Operation:

Continuous Mode

Frequency Range:

0.25 Hz to 10 kHz

Frequency Resolution:

4%

Frequency Accuracy:

3%

Duty Cycle Range:

3% to 97% (0.25 Hz to 1 kHz); 6% to 94% (1 kHz to 10 kHz)

Duty Cycle Resolution:

4%

Duty Cycle Accuracy:

6% of setting ± 2%

Pulsed Mode
Pulse Width:

50

µ

s ± 3% minimum; 4 s ± 3% maximum

Transient Current Level (0 to 12 A and 0 to 120 A ranges):

Resolution:

52 mA (12 A range); 520 mA (120 A range)

Accuracy:

± 0.15% ± 160 mA (12 A range); ± 0.15% ± 700 mA (120 A range)

Temperature Coefficient:

150 ppm/

°

C ± 10 mA/

°

C

Transient Resistance Level (0.017 to 0.5

, 0.5

to 500

, and 5

to 5 k

ranges):

Resolution:

2.2 m

(0.5

range); 8.7 mS (500

range); 0.87 mS (5 k

range)

Accuracy:

± 0.8% + 7 m

with > 12 A at input (0.5

range)

± 0. 3% + 26 mS with

6 V at input (500

range)

± 0.3% + 18 mS with

6 V at input (5 k

range)

Transient Voltage Level (0 to 60 V):

Resolution:

260

V

Accuracy:

± 0.15% ± 300 V

Temperature Coefficient:

150

ppm/

°

C ± 5 mV/

°

C

Current Readback:

Resolution:

34 mA (via GPIB); 100 mA (front panel)

Accuracy:

(after 30 minute wait): ± 0.1% ± 110 mA

Temperature Coefficient:

100

ppm/

°

C ± l mA/

°

C

Voltage Readback:

Resolution:

17 mV (via GPIB); 20 mV (front panel)

Accuracy:

± 0.1% ± 45 mV

Temperature Coefficient:

100 ppm/

°

C ± 2 mV/

°

C

Maximum Readback Capability:

65 to 70 V (typical)

Power Readback:

Accuracy:

± 0.2% ± 8 W