beautypg.com

300xac specifications – Atec Associated-PowerTech-300XAC Series User Manual

Page 6

background image

8

300XAC Specifications

Measurement (Total)
Linking Parallel 1Φ2W

310XAC

320XAC

340XAC

360XAC

Voltage

Range

0.0 - 400.0 V

Accuracy

± (1% of reading + 2 counts) > 5 V

± (1% of reading + 5 counts) > 5 V

Frequency

Range

0.0 - 1000.0 Hz

Accuracy

L

± 0.1 Hz @ 0.0 - 500 Hz

H

± 0.2 Hz @ 501 - 1000 Hz

Current (rms)

Range

2

0.00 A - 26.00 A

0.00 A - 52.00 A

0.00 A - 104.0 A

0.00 A - 156.0 A

3

0.00 A - 39.00 A

0.00 A - 78.00 A

0.00 A - 156.0 A

0.00 A - 234.0 A

Accuracy

L

± (1.5% of reading +15 counts) x # of Linked Units

@ 40.0 - 70.0 Hz & Current is > 1.0 A

± (1.5% of reading +15

counts) x Link Units @ 40.0

- 70.0 Hz and current(r.m.s.)

> 2.00 A, ± (1.5% of reading

+15 counts) x Link Units

@ 70.1 - 1000 Hz, and

current(r.m.s.) > 10.00 A

± (1.5% of reading +15

counts) x Link Units @ 40.0

- 70.0 Hz and current(r.m.s.)

> 3.00 A, ± (1.5% of read-

ing +15 counts) x Link Units

@ 70.1 - 1000 Hz, and

current(r.m.s.) > 15.00 A

H

± (1.5% of reading +15 counts) x # of Linked Units

@ 70.1- 1000 Hz & Current is > 5.00 A

Power (W)

Range

2

0 W - 2600 W

0 W - 5200 W

0 W -10400 W

0 W - 15600 W

3

0 W - 3900 W

0 W - 7800 W

0 W - 15600 W

0 W - 23400 W

Accuracy

± (2% of reading + 10 counts) x (# of Linked Units) at PF ≥ 0.2, 40 - 500 Hz, and Current > 5.0 A

± (2% of reading + 10 counts) x (# of Linked Units) at PF ≥ 0.3, 501 - 1000 Hz, and Current > 5.0 A

Power Apparent

(VA)

Range

2

0 W - 2600 VA

0 W - 5200 VA

0 W -10400 VA

0 W - 15600 VA

3

0 W - 3900 VA

0 W - 7800 VA

0 W - 15600 VA

0 W - 23400 VA

Accuracy

V x A, Calculated Value

Power Reactive

(Q)

Range

2

0 W - 2600 VA

0 W - 5200 VA

0 W -10400 VA

0 W - 15600 VA

3

0 W - 3900 VA

0 W - 7800 VA

0 W - 15600 VA

0 W - 23400 VA

Accuracy

√(VA)² - (W)², Calculated Value

Power Factor

Range

0 - 1.000

Accuracy

W / VA, Calculated and displayed to three significant digits

Measurement (Total)

Linking Polyphase 1Φ3W

310XAC

320XAC

340XAC

360XAC

Voltage

Range

2

L1 Voltage + L2 Voltage

Accuracy

L

Summation of linked sources, Calculated and displayed to one significant digit

Frequency

Range

0.0 - 1000.0 Hz

Accuracy

L

± 0.1 Hz @ 0.0 - 500 Hz

H

± 0.2 Hz @ 501 - 1000 Hz

Current (rms)

Range

2

(L1 Current + L2 Current)/2

Accuracy

± (1% of reading + 5 counts) at 40 - 70 Hz

± (1% of reading + 5 counts) at 70.1 - 500 Hz, and output current (r.m.s.) > 0.200 A

± (1% of reading + 5 counts) at 501 - 1000 Hz, and output current (r.m.s.) > 0.300 A

Power (W)

Range

2

L1 Power + L2 Power

Accuracy

2

L1 Power + L2 Power, Calculated Value

Power Apparent

(VA)

Range

2

L1 VA + L2 VA

Accuracy

2

L1 VA + L2 VA, Calculated Value

Power Reactive

(Q)

Range

2

L1 VAR + L2 VAR

Accuracy

2

L1 VAR + L2 VAR, Calculated Value

Power Factor

Range

0 - 1.000

Accuracy

(L1 P + L2 P) / (L1 VA + L2 VA), Calculated and displayed to three significant digits