6
INPUT
310XAC
320XAC
340XAC
360XAC
Phase
1
Φ
1
Φ
or 3
Φ
Voltage
90 - 264 VAC
180 - 264 VAC
180 - 457 VAC
Frequency
47 - 63 Hz
OUTPUT
Voltage
5 - 300 V
Max Power
1 kVA
2 kVA
4 kVA
6 kVA
Max Current 1Φ 0 - 150 V
9.2 A @ 110 V
18.4 A @ 110 V
36.8 A @ 110 V
55.2 A @ 110 V
0 - 300 V
4.6 A @ 220 V
9.2 A @ 220 V
18.4 A @ 220 V
27.6A @ 220 V
Phase
1
Φ
(Parallel/Poly-Phase Linking for 1
Φ
3W or 3
Φ
4W)
Frequency
40.0 - 1000 Hz
THD
<1% (Resistive Load)
Crest Factor
Inrush CF ≥ 3 at 110 V, Continuous Current CF ≥ 3 at 110 V
Line Regulation
± 0.1 V
Load Regulation
±0.5 V
DC OUTPUT VOLTAGE
Voltage
5 - 420 V
Max Power
1000 W
2000 W
4000 W
6000 W
Max Current 1Φ 0 - 210 V
4.8 A
9.6 A
19.2 A
28.8 A
0 - 420 V
2.4 A
4.8 A
9.6 A
14.4 A
Ripple & Noise
< 3.0 V p-p
< 4.0 V p-p
MEASUREMENT
Voltage
Range
0.0 - 400.0 V
Accuracy
± (1% of reading + 2 counts) > 5 V
± (1% of reading + 5 counts) > 5 V
Frequency
Range
0.0 - 1000 Hz
Accuracy
0.0 - 500 Hz ± 0.1 Hz, 501 - 1000 Hz ± 0.2 Hz
Current (rms)
Range
0.005 A - 13.00 A
0.005 A - 26.00 A
0.05 A - 52.00 A
0.05 A - 78.00 A
Accuracy
± (1% of reading + 5 counts)
± (1% of reading + 5 counts) @ 40 - 100 Hz, ± (1% of
reading + 5 counts) @ 101 - 500 Hz > 0.1 A, ± (1% of
reading + 5 counts) @ 501 - 1000 Hz > 0.2 A
Current Peak
Range
0.0 A - 38.0 A
0.0 A - 76.0 A
0.0 A - 152 A
0.0 A - 228 A
Accuracy
± (1% of reading + 5 counts)
Power
Range
0.0 W - 1300 W
0.0 W - 2600 W
0.0 W - 5200 W
0.0 W - 7800 W
Accuracy
L
± (2% of reading + 15 counts) at PF ≥ 0.2
± (2% of reading + 5 counts) at PF ≥ 0.2
H
± (2% of reading + 5 counts) at PF ≥ 0.2
Power
Apparent (VA)
Range
0.0 VA - 1300 VA
0.0 VA - 2600 VA
0.0 VA - 5200 VA
0.0 VA - 7800 VA
Accuracy
V×A , Calculated value
Power
Reactive (Q)
Range
0.0 VAR - 1300 VAR
0.0 VAR - 2600 VAR
0.0 VAR - 5200 VAR
0.0 VAR - 7800 VAR
Accuracy
√(VA)²-(W)², Calculated value
Power Factor
Range
0.000 - 1.000
Accuracy
W/VA, Calculated and displayed to three significant digits
Crest Factor
Range
0.0 - 10.0
Accuracy
Apeak / Arms, Calculated and displayed to two significant digits
OPTIONS
Grounded Neutral
Option 2
Yes
GPIB Interface
Option 3
Yes
7 Remote Memory Option 4
Yes
Ethernet Interface Option 6
Yes
Linking Card
Option 8
Yes
GENERAL
Operation Environment
0 - 40ºC / 20 - 80% RH
Dimensions W x H x D – inches/mm
16.92 x 5.26 x 20.87 in
16.92 x 5.26 x 20.87 in
16.92 x 10.51 x 19.69 in
16.92 x 15.77 x 19.69 in
430 x 133.5 x 530 mm
430 x 133.5 x 530 mm
430 x 267 x 500 mm
430 x 400.5 x 500 mm
Net Weight Lbs. (kg)
44 lbs (20 kg)
46.3 lbs (21 kg)
110.2 lbs (50 kg)
117 lbs (53 kg)
Specifications subject to change