5
Table 60501-1 Specifications and Supplemental Characteristics (continued)
Current Slew Rate:*
Rate #
30 A Range Step
3 A Range Step
Transition Time
1
0.5 A/ms
0.05 A/s
8.0 ms
2
1.2 A/ms
0.12 A/s
3.2 ms
3
2.5 A/ms
0.25 A/ms
1.6 ms
4
5 A/ms
0.5 A/ms
800
µ
s
5
12 A/ms
1.2 A/ms
320
µ
s
6
25 A/ms
2.5 A/ms
160
µ
s
7
0.05 A/
µ
s
5 A/ms
80
µ
s
8
0.12 A/
µ
s
12 A/ms
32
µ
s
9
0.25 A/
µ
s
25 A/ms
16
µ
s
10
0.5 A/
µ
s
0.05 A/
µ
s
12
µ
s
11
1.2 A/
µ
s
0.12 A/
µ
s
12
µ
s
12
2.5 A/
µ
s
0.25 A/
µ
s
12
µ
s
*AC performance specified from 3 to 60 V.
Voltage Slew Rate:
Rate #
Voltage Range Step
Transition Time*
1
1 V/ms
8.0 ms
2
2.5 V/ms
3.2 ms
3
5 V/ms
1.6 ms
4
10 V/ms
800
µ
s
5
25 V/ms
320
µ
s
6
50 V/ms
160
µ
s
7
0.1 V/
µ
s
85
µ
s
8
0.25 V/
µ
s
85
µ
S
9
0.5 V/
µ
s
85
µ
S
*Transition time based on low capacitance current source.
Resistance Slew Rate
(2
Ω
range): Uses the value programmed for voltage slew rate.
Resistance Slew Rate
(2 k and 10 k
Ω
ranges): Uses the value programmed for current slew rate.
Transient Current Overshoot (When programmed from 0A):
Range
Transient Current Level
Current Slew Rate
Overshoot*
30 A
3-30 A
All slew rates
0
1.5 A
0.5 A/
µ
s to 2.5 A/
µ
s
6%
1.5 A
0.5 A/ms to 0.25 A/
µ
s
0
3 A
3 A
All slew rates
0
1.5 A
0.13 A/
µ
s and 0.25 A/
µ
s
3%
1.5 A
0.05 A/ms and 0.05 A/
µ
s
0
*Overshoot may be higher during first five seconds of programming if unit has been operating at full current. Overshoot
values assume a total inductance of l
µ
H, or less, in the load leads connected to the D.U.T.