Dc mode output, Ac + dc mode output, Ac input – Atec California-Instruments-15001iX User Manual
Page 6: System, Ix series - specifications, Remote control, Output relay, Output impedance, Power, Waveforms
Output Relay
Push button controlled or bus
controlled output relay
Output impedance
Programmable Z on 3001
iX,
5001
iX and 15003iX for 50 Hz
fundamental
Resistive:
range
17 - 1000 m
Ω
resolution
4 m
Ω
accuracy
2 % FS
Inductive:
range
230 - 1000
µ
H
resolution
4
µ
H
accuracy
2 % FS
DC Mode Output
Maximum DC power at full scale
of DC voltage range:
Model:
Power
3001
iX
1500 W
5001
iX
2500 W
10001
iX
5000 W
15001
iX
7500 W
15003
iX
2500 W/ш 3ш
7500 W/ш 1ш
Voltage Ranges
User selectable voltage range
combinations:
Range:
High
Low
270 V
135 V
300 V
150 V
Load Regulation
see AC mode
Line Regulation
see AC mode
Output Noise
< 250 mV
rms
Typ
(20 kHz to 1 MHz)
< 500 mV
rms
Max
Max. DC Current Capability
Maximum DC current in lowest
DC range pair:
Model
270
range
135
range
3001
iX
5.65
11.1
5001
iX
9.25
18.5
10001
iX
18.5
37.0
15001
iX
27.75
55.5
15003
iX 1ш
27.75
55.5
3ш
9.25
18.5
Current Limit
Programmable
from 0 A to max. current for
selected range.
AC + DC Mode Output
Power
Full AC power if DC component
is less than 20 % of full scale
voltage. Full DC power if DC
component is above 20 %.
System
Non Volatile Memory storage
16 complete instrument setups
200 user defined waveforms
Waveforms
Waveform Types
•
Sine
•
Square
•
Clipped Sine, 0 - 20 % THD
•
User defined
User defined waveform storage
Four groups of 50 user defined
arbitrary waveforms of 1024
points for a total of 200. One
group can be active at a time.
Transient Programming
Transient Types
Voltage: drop, step, sag, surge,
sweep
Frequency: step, sag, surge,
sweep
Voltage and Frequency: step,
sweep
Transient List Parameters:
Voltage, Frequency, Time or
cycles, Slew rate, Waveform
shape, Phase angle, Repeat
Transient lists storage
up to 32 transient steps per list
Time resolution
1 msec
Time range
1 msec - 9999 sec
Maximum slew rate
50
µ
sec for 10% to 90% of full
scale change into resistive load
Waveform Acquisition
Channels
Voltage and Current for each
phase.
Memory Depth
4096 samples/channel.
Maximum Sample Rate
39.0625 Ks/s.
Triggering
Auto, Phase, Transient.
Trigger Delay
Pre-trigger
0 - 104 msec 1ø
0 - 312 msec 3ø
Post-trigger
0 - 1000 msec.
Display
Front panel Graphics Display
with cursors.
Bus Interface
Full bus access to waveform
acquisition system.
Remote Control
IEEE-488 Interface
IEEE-488 (GPIB) talker listener.
Subset:
AH1, C0, DC1, DT1, L3, PP0,
RL2, SH1, SR1, T6
IEEE-488.2 SCPI Syntax
RS232C Interface
9 pin D-shell connector
Handshake: CTS, RTS
Databits:
7,8
Stopbits:
1,2
Baud rate:
9600, 19200,
38400
IEEE-488.2 SCPI Syntax
Supplied with RS232C cable
System Interface
Inputs:
Remote shutdown
External Sync
Outputs:
Function Strobe
AC Input
Voltage
Model 3001iX:
187 - 264 V
AC
,(L-N, 1 Phase)
All other models:
Standard:
187 - 264 V
AC
,(L-L, 3 Phase)
Option -400:
360 - 528V
AC
,(L-L, 3 Phase)
(Input range must be specified
when ordering)
Current
Input Line Current (per phase)
Model:
187-
264V
360-
528V
3001
iX
30 A
N/A
5001
iX
24 A
12 A
10001
iX
48 A
24 A
15001
iX
72 A
36 A
15003
iX
72 A
36 A
Inrush Current per chassis
< 14 A rms. / 84 A
peak
for 200
µ
s
@ 187-264 V
< 8 A rms. / 36 A
peak
for 400
µ
s
@ 360-528 V
Line Frequency:
47 - 63 Hz
Efficiency:
75 % typical
Power Factor:
0.6 typical
Hold-up Time:
At least 10 ms
iX Series - Specifications
1
Note 1: Specifications are warranted over an ambient temperature range of 25°± 5° C.
Unless otherwise noted, specifications are per phase for a sinewave with a resistive
load and apply after a 30 minute warm-up period.