Operating Modes

AC, DC or AC + DC

AC Mode Output

Frequency

16.00 Hz - 500.0 Hz

Power

Maximum AC power per phase
at full scale voltage:

Model:

Power

3001

iX

3000 VA

5001

iX

5000 VA

10001

iX

10000 VA

15001

iX

15000 VA

15003

iX

(with mode-iX)

5000 VA/ш 3ш

15000 VA/ш 1ш

Power Factor

0 to unity at full output VA

AC Voltage

Ranges

User selectable

voltage range pairs:

Range:

Low

High

Max Vrms

135 V

270 V

Max Vrms

150 V

300 V

Load Regulation

± 0.5% DC to 100 Hz
± 0.6 % 100 Hz to 500 Hz in high
voltage range
± 2.2 % 100 Hz to 500 Hz in low
voltage range

Line Regulation

< ± 0.1% for 10

% line change
Output Noise

< 250 mV

rms

typ.

(20 kHz to 1 MHz)

< 500 mV

rms

max.

Harmonic Distortion (linear load)

Less than 1% from 16 - 66 Hz
Less than 2% at 400 Hz

DC Offset

< 20 mV

External Modulation

depth:

0 - 10 %

Isolation Voltage

300 V

rms

output to chassis

AC Current

Peak Repetitive AC Current

Model

High

range

Low

range

3001

iX

96.0

110.0

5001

iX

96.0

110.0

10001

iX

192.0

220.0

15001

iX

288.0

330.0

15003

iX 1ш

288.0

330.0

96.0

110.0

AC Current

Steady State AC Current

Model

270 V

range

135 V

range

3001

iX

11.1

22.2

5001

iX

18.5

37.0

10001

iX

37.0

74.0

15001

iX

55.5

111.0

15003

iX 1ш

55.5

111.0

18.5

37.0

Model

300 V

range

150 V

range

3001

iX

10.0

20.0

5001

iX

16.7

33.3

10001

iX

33.3

66.7

15001

iX

50.0

100.0

15003

iX 1ш

50.0

100.0

16.7

33.3

Programming Accuracy

Voltage (rms): ± 0.5 % of range,
16 to 400 Hz
Frequency: ± 0.01 % of
programmed value.
Current Limit: - 0 % to + 7 % of
programmed value + 0.5 A.
Phase:

< 1.5° with

balanced load @ 50/60 Hz.

Programming Resolution

Voltage (rms): 100 mV
Frequency:
0.01 Hz from 16 Hz to 81.91 Hz
0.1 Hz from 82.0 Hz to 500.0 Hz
Current Limit:
0.1 A for 5001iX and 15003iX.
1.0 A for 10001iX and 15001iX.
Phase:

0.1°

iX Series - Specifications

1

Standard Measurements (5001iX)

Parameter

Range

Accuracy

*

(±)

Resolution

*

AC Measurements

Frequency

16.00 - 500.0 Hz

0.01% + 0.01 Hz

0.01 Hz

< 100 Hz

100 - 500

Hz

RMS Voltage

0 -330 V

50 mV

100 mV

10 mV

RMS Current

0 - 40 A

50 mA

100 mA

1 mA

Peak Current

0 - 119 A

50 mA

100 mA

1 mA

Crest Factor

0.000 - 6.000

0.05

0.05

0.01

Real Power

0 - 6 kW

5 W

5 W

1 W

Apparent
Power

0 - 6 kVA

10 VA

20 VA

1 VA

Power Factor

0.00 - 1.00

0.01

0.01

0.01

DC Measurements

DC Voltage

0 - 420 V

500 mV

10 mV

DC Current

0 - 120 A

500 mA

1 mA

Power

0 - 6 kW

50 W

1 W

* Measurement system bandwidth = DC to 19.5 kHz. Accuracy specifications are valid above 100
counts. Current and Power Accuracy specifications are times two for 10001iX and times three for
15001iX. For 10001iX and 15001iX, resolution decreases by factor of 10, ranges for current and
power increases by factor of three.

Harmonics Measurements

Parameter

Range

Accuracy

*

(±)

Resolution

Frequency

Fundamental

16.00-500.0 Hz

0.01% + 0.01 Hz

0.01 Hz

Harmonics

32.00 Hz - 19.5 kHz

0.01 Hz

Phase

0.0 - 360.0°

2° typ.

0.5°

Voltage

Fundamental

250 mV

10 mV

Harmonics 2 - 50

0.1% + 250 mV+0.1% /1 kHz

10 mV

Current

Fundamental

50 mA

10 mA

Harmonics 2 - 50

0.1% + 50 mA +0.1% /1 kHz

10 mA

* Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for
three phase mode. Harmonics frequency range in three phase mode is 32 Hz - 6.67 kHz. Resolution
decreases by factor of 10 for 10001iX and 15001iX.

This manual is related to the following products: