Sx s, Eries, Pecifications – Atec Elgar-501b User Manual
Page 6: Specifications, Single-phase output power, Dual-phase output power, Three-phase output power, Model power output input physical comments

Elgar
■
1.800.733.5427
■
858.450.0085
■
Fax 858.458.0267
■
9250 Brown Deer Road, San Diego, CA 92121
■
www.elgar.com
■
email: [email protected]
25
SX S
ERIES
S
PECIFICATIONS
SPECIFICATIONS
OUTPUT
Voltage Range: 0-65/130/260 VAC (varies
per model). Specific output range is
selected by jumper change on rear panel.
Consult Elgar for other voltage ranges.
Rated Power Voltage Range: Full rated
VA from 55-65 VAC, 110-130 VAC, or
220-260 VAC over a ±10% input and rated
PF range. Continuous duty at 150% of
rated capacity at 55°C*
Load Power Factor: Unity to ±0.7 PF to
rated VA with an output voltage
adjustment range of 80-100% of full scale*
Frequency Range: 45 Hz to 1kHz
Total Harmonic Distortion:
0.5% from 45 Hz to 1 kHz with linear load
1.0% from 45 Hz to 75 Hz with pulsed load
4.0% from 75 Hz to 450 Hz with pulsed load
Load Regulation: ±1% from 45 Hz to
450 Hz with pulsed load or from 45 Hz to
1 kHz with linear load
Line Regulation: ±0.25% at rated load for
a ±10% input change at full scale output
voltage
Response Time: <2 ms
AC Noise Level: 70 dB below full output
voltage with input grounded
INPUT
Voltage: 115/208/230 VAC, ±10% (208 VAC
not available on 501 SX.) User selectable
(See model description on page 23)
Frequency: 47 to 63 Hz (400 Hz option,
special order)
Efficiency: Up to 45%
GENERAL
Operating Temperature Range: 0° to
+55°C
Operating Humidity Range: Up to 95%
non-condensing
Metering: 0 to 300 VAC output voltmeter,
±3% accuracy
Controls: Input power switch/circuit
breaker and pilot light. Full range, 10-turn
output voltage control potentiometer
* See power derating curve on page 23.
Single-Phase Output Power
Model
Power
Output
Input
Physical
Comments
Total VA
Vol. Range Max Current
Frequency Range
Voltage and Nominal/Max
Height and Depth
Weight
(RMS)L-N
(RMS)
1
(Hz)
Phase
(kVA)
2
(in/mm)
(lbs/kg)
501 SX-X4
500
0-65
11.5/36
45 to 1k
115 or 230,
1.5/2.2
5.25/133
H
80/36
Net
0-130
5.8/18
1ø
21/533 D
88/40
Ship
0-260 2.9/9
1001 SX-X4
1000
0-65
23.1/72
45 to 1k
115, 208 or
3.0/4.2
7.00/178
H
130/59
Net
0-130 11.5/36
230,
1ø
21/533
D
140/64
Ship
0-260
5.8/18
1751 SX-X4
1750
0-65
40.4/120
45 to 1k
115,108 or
5.2/7.5
12.25/311
H
195/89
Net
&
0-130
20.2/60
230, 1ø
21/533
D
205/93
Ship
1751 SXE-2X
0-260
10.1/30
1751 SXE-24 only
Dual-Phase Output Power
1000 SX-2-X4
1000
0-65
11.5/36
45 to 1k
115 or 230,
3.0/4.4
10.50/267
H
160/73
Net
2 ea 501 SX in 2ø 90°, 1ea 400 SR,
0-130
5.8/18
1ø
21/533
D
176/80
Ship
1ea signal cable
0-260
2.9/9
2000 SX-2-X4
2000
0-65
23.1/72
45 to 1k
115,208 or
6.0/8.4
14/356
H
260/118
Net
2ea 1001 SX in 2ø 90°, 1ea 400 SR,
0-130 11.5/36
230,
1ø
21/533
D
280/127
Ship
1ea signal cable
0-260
5.8/18
3500 SX-2-X4
3500
0-65
40.4/120
45 to 1k
115, 208 or
10.5/15.0
24.50/622
H
390/177
Net
2 ea 1751 SX or 1751 SXE in 2ø 90°,
&
0-130
20.2/60
230, 1ø
21/533 D
410/186
Ship
1 ea 400 SR, 1 ea signal cable
3500 SXE-2-2X
0-260
10.1/30
3500 SXE-2-24 only
Three-Phase Output Power
1500 SX-3-X4
1500
0-65
11.5/36
45 to 1k
115 or 230,
4.5/6.6
15.75/400
H
240/109
Net
3 ea 501 SX (4 wire Y),
0-130
5.8/18
1ø or 3ø
21/533
D
264/120
Ship
2 ea 400 SR, 1 ea signal cable
0-260
2.9/9
3000 SX-3-X4
3000
0-65
23.1/72
45 to 1k
115, 208 or
9.0/12.6
21/533
H
390/177
Net
3 ea 1001 SX (4 wire Y)
0-130
11.5/36
230, 1ø or 3ø
21/533
D
420/191
Ship
2 ea 400 SR, 1 ea signal cable
0-260
5.8/18
5250 SX-3-X4
5250
0-65
40.4/120
45 to 1k
115, 208 or
15.7/22.5
36.75/933
H
585/266
Net
3 ea 1751 SX or 1751 SXE (4 wire Y),
&
0-130
20.2/60
230, 1ø or 3ø
21/533 D
615/280
Ship
2 ea 400 SR, 1ea signal cable
5250 SXE-3-2X
0-260
10.1/30
5250 SXE-3-24 only
1
All SX models specified are at 150% of nominal output current into a linear resistive load.
2
Maximum volt/amps under worst case conditions of load and input line at 150% capacity.