beautypg.com

Digital voltmeter (specifications are typical), Connectivity – Atec Agilent-3000-X Series User Manual

Page 24

background image

24

Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget

Performance characteristics

* Gaussian Pulse: 4 Vpp maximum into Hi-Z; 2 Vpp maximum into 50 ohms.
** Sinc, Cardiac and Gaussian Pulse: ±1.25 V into Hi-Z; +- 625 mV into 50 ohms
*** Full resolution is not available at output due to internal attenuator stepping.

WaveGen – Built-in function/arbitrary waveform generator (specifications are typical)

(Continued)

Frequency

• Sine wave and ramp accuracy:

◦ 130 ppm (frequency < 10 kHz)

◦ 50 ppm (frequency > 10 kHz)

• Square wave and pulse accuracy:

◦ [50+frequency/200] ppm (frequency < 25 kHz)

◦ 50 ppm (frequency ≥ 25 kHz)

• Resolution: 0.1 Hz or 4 digits, whichever is larger

Amplitude

• Range:

◦ 20 mVpp to 5 Vpp into Hi-Z**

◦ 10 mVpp to 2.5 Vpp into 50 ohms**

• Resolution: 100 μV or 3 digits, whichever is higher
• Accuracy: 2% (frequency = 1 kHz)

DC offset

• Range:

◦ ±2.5 V into Hi-Z**

◦ ±1.25 V into 50 ohms**

• Resolution: 100 μV or 3 digits, whichever is higher
• Accuracy (waveform modes): ± 1.5% of offset setting ± 1% of amplitude ± 1 mV
• Accuracy (DC mode): ± 1.5% of offset setting ± 3 mV

Trigger output

Trigger output available on Trig out BNC

Main Output

• Impedance : 50 ohms typical
• Isolation: not available, main output BNC is grounded
• Protection: overload automatically disables output

Digital voltmeter (specifications are typical)

Functions

ACrms, DC, DCrms, Frequency

Resolution

ACV/DCV: 3 digits Frequency: 5.5 digits

Measuring rate

100 times/ second

Autoranging

Automatic adjustment of vertical amplification to maximize the dynamic range of measurements.

Range meter

Graphical display of most recent measurement, plus extrema over the previous 3 seconds

.

Connectivity

Standard ports

One USB 2.0 hi-speed device port on rear panel. Supports USBTMC protocol.
Two USB 2.0 hi-speed host ports, front and rear panel
Supports memory devices and printers

Optional ports

GPIB, LAN (10/100Base-T), WVGA video out

Trigger out

BNC connector on the rear panel. Supported modes: triggers, mask, and waveform generator
sync pulse