E2695A 8-GHz differential SMA
probe head

allows you to connect

two SMA cables to make a differential
measurement on

a single scope channel.

N5381A 13-GHz high-
bandwidth solder-in differential
probe head

provides maximum

bandwidth and minimizes capacitive loading
to ≤ 210 fF. Variable spacing from
0.2 to 3.3 mm (8 to 130 mills).

E2679A 6-GHz extremely
small single-ended, solder-in
probe heads

for probing even the

hardest-to-reach single-ended signals.

E2677A 12-GHz solder-in
differential probe head

can be

attached to very-small-geometry circuits
for measuring both single-ended and
differential signals. External mini-coaxial
resistors facilitate wider span but have
increased high-frequency response
variation relative to N5381A.

N5425A 13-GHz high-
bandwidth solder-in differential
ZIF probe head and N5426A
ZIF tip

provides maximum bandwidth

with the industry’s first lead-free solder-
in probe solution in an economical
replaceable tip form factor.

N5451A 9-GHz/5-GHz long-wire
ZIF tip

provides a high-bandwidth

economical replaceable solder-in tip with
extra reach (9 GHz with 7 mm and 5 GHz
with 11 mm wire).

InfiniiMax offers you the high-
est performance

available for mea-

suring differential and single-ended signals,
with flexible connectivity solutions for
today’s high-density ICs and circuit boards.

InfiniiMax probes have fully
characterized performance

for all

of their various probe heads. This includes:
• Swept frequency response plot
• Common mode rejection versus

frequency plot

• Impedance versus frequency plot
• Time-domain probe loading plot
• Time-domain probe tracking plot

One-year standard warranty

on

active probes and a variety of Agilent
support options to choose from.

Controlled impedance
transmission lines

in every probe

head deliver full performance versus the
performance limitations introduced by
traditional wire accessories.

Probe interface software

allows

you to save the calibration information for
up to 10 different probe heads per channel
and will automatically retrieve calibration
data for a probe amplifier when attached to
the scope.

High-input impedance active
probes

minimize loading, support

differential measurements and DC offset,
and can compensate for cable loss.

Probe calibration software

delivers the most accurate probe
measurements and linear phase response
and allows various probe combinations to
be deskewed to the same reference time.

A flat frequency response

over

the entire probe bandwidth eliminates the
distortion and frequency-dependent loading
effects that are present in probes that have
an in-band resonance.

N5426A

N5451A

InfiniiMax II: The World’s best high-speed probing system
just keeps getting better