I/ix series : product specifications – Atec California-Instruments-i-iX_SeriesII User Manual
Page 6

www.ProgrammablePower.com
174
i/iX Series : Product Specifications
Measurements
Output Parameter
i Series
iX Series
Current Limit Range
Programmable 0 to 100% of range for all ranges
Programmable 0 to 100% of range for all ranges
Current Limit Resolution
0.1 Arms
0.1 Arms
Current Limit Accuracy
± 0.5 A
± 0.5 A
Frequency Range
16.00 - 81.91 Hz (0.01 Hz resolution)
81.0 – 819.1 Hz (0.1 Hz resolution)
820 – 1000 Hz (1 Hz resolution)¹
16.00 - 81.91 Hz (0.01 Hz resolution)
81.0 – 819.1 Hz (0.1 Hz resolution)
820 – 1000 Hz (1 Hz resolution)¹
Frequency Accuracy
± 0.01% of programmed value
± 0.01% of programmed value
DC Offset Voltage
Less than 20 mV with linear load.
Less than 20 mV with linear load.
Output Impedance Range
n/a
Rmin to 1000 mΩ
Lmin to 1000 μH
Output Impedance Resolution
n/a
4 mΩ
4 μH
Output Impedance Accuracy
n/a
± 2% F.S. at 796 μH and 400 mΩ
Output Noise (20 kHz to 1 MHz)
<250 mV rms (typ),
<500 mV rms (max)
<250 mV rms (typ),
<500 mV rms (max)
1 Note: AC voltage in 300V range derates from 300 Vrms max. at 500 Hz to 150 Vrms max. at 1000 Hz.
Measurements : Peak AC Current
Output Parameter
i Series
iX Series
3001i/iX
5001i/iX
110 A for 150 V range,
92 A for 300 V range
110 A for 150V range,
92 A for 300 V range,
10001i/iX
220 A for 150 V range,
184 A for 300 V range
220 A for 150 V range,
184 A for 300 V range
15001i/iX
330 A for 150 V range,
276 A for 300 V range
330 A for 150 V range,
276 A for 300 V range
Crest Factor
Up to 5:1
Up to 5:1
AC Measurements
Parameter
Range
Accuracy (±)
Resolution
Frequency
16.00 - 1000 Hz
2 counts
0.01: 16 to 81.91 Hz
0.1: 82.0 to 819.0 Hz
1: 820 to 1000 Hz
RMS Voltage
0 - 300 Volts
0.25V + 0.1%, <100 Hz
0.25V + 0.2%, 100-1000 Hz
0.01 Volt
RMS Current
0 - 40 Amps
0.25A + 0.1%, <100 Hz
0.25A + 0.2%, 100-1000 Hz
0.001 Amp
Peak Current
0 - 119 Amps
0.5A + 0.2%, <100 Hz
0.5A + 0.5%, 100-1000 Hz
0.01 Amp
VA Power
0 – 6000 VA
10 VA + 0.1%, <100 Hz
20 VA + 0.2%, 100-1000 Hz
1 VA
Real Power
0 – 6000 W
10 W + 0.1%, <100 Hz
20 W + 0.2%, 100-1000 Hz
1 W
Power Factor (>0.2kVA)
0 - 1.00
0.01
Accuracy specifications apply above 100 counts. Current and Power Accuracy specifications are times two for 10001iX and times three for 15001iX. For 10001iX and 15001iX,
resolution decreases by factor of 10, ranges for current and power increases by factor of three. Measurement bandwidth is limited to 16 Khz.
DC Measurements
Parameter
Range
Accuracy (±)
Resolution
Voltage
0 – 400 Volts
0.4 Volts
0.01 Volt
Current
0 – 40 Amps
0.1 Amps
0.001 Amp
Power
0 – 6000 W
20 W
1 W
Accuracy specifications apply above 100 counts. Current and Power Accuracy specifications are times two for 10001iX and times three for 15001iX. For 10001iX and 15001iX,
resolution decreases by factor of 10, ranges for current and power increases by factor of three.