AC Mode Output
Frequency
Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz;
See V-F rating chart. below)
Total Power
3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA per phase, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX:
15000 VA, 15003i/iX: 5000 VA/ш 3ш, with mode iX: 15000 VA 1ø
Load Power Factor
0 to unity at full output VA
i/iX Series II : Product Specifications
Operating Modes
iX Series II
AC, DC or AC+DC
i Series II
AC or DC
AC Mode Voltage
Voltage Ranges
Range
V Low
V High
Load Regulation
(with ALC on):
< 0.2%
AC
0-150 V
0-300 V
Load Regulation
(with ALC off):
< 0.5% DC to 100 Hz, < 0.6% 100 Hz to 500 Hz in high voltage range,
< 2.2% 100 Hz to 500 Hz in low voltage range, < 3% 500 Hz to 1000 Hz
AC+DC
0-150 V
0-300 V
Line Regulation:
< 0.1% for 10% line change
Output Noise (20 kHz to 1 MHz)
< 250 mVrms typ., < 500 mVrms max
Harmonic Distortion (Linear)
< 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load)
DC Offset
< 20 mV
External Amplitude Modulation
Depth: 0 - 10 %, Frequency: DC - 2 KHz
Isolation Voltage
300 Vrms output to chassis
Voltage slew rate
200 µs for 10% to 90% of full scale change into resistive load, 0.5V / µSec
AC Mode Current
Steady State AC Current
Model
3001i/iX
5001i/iX
9003i/iX
3ø
10001i/iX
15001i/iX
15003i/iX
3ø
300 V range
11.1
18.5
11.1 /
ш
37.0
55.5
18.5 /
ш
150 V range
22.2
37.0
22.2 /
ш
74.0
111.0
37.0 /
ш
Note: Constant power mode provides increased current at reduced voltage (See chart below)
Peak Repetitive AC Current
Model
3001i/iX
5001i/iX
9003i/iX 3ø
10001i/iX
15001i/iX
15003i/iX 3ø
High range
96.0
96.0
96.0 /
ш
192.0
288.0
96.0 /
ш
Low range
110.0
110.0
110.0 /
ш
220.0
330.0
110.0 /
ш
Programming Accuracy
Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed value,
Phase: < 1.5° with balanced load at 50/60 Hz
Programming Resolution
Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz,
Current Limit: 0.1 A, Phase, 0.1°
Output Relay
Push-button controlled or bus controlled output relay
Output Impedance (iX Only)
Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental
Resistive
Range: 17 - 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS
Inductive
Range: 230 - 1000 µH, resolution: 4 µH, accuracy: 2 % FS
DC Mode Output
Power (Max at full scale of
DC Voltage Range):
3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ш 3ш, 6300 W 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W,
15003i/iX: 3500 W/ш 3ш
Voltage Ranges
Range: Low: 200 Vdc,
High: 400 Vdc
Line Regulation
< 0.1% FS or 10% line change
Output Noise
< 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz)
Max DC Current (Maximum current
at 65% of V Range)
Model
3001i/iX
5001i/iX
9003i/iX
3ø
10001i/iX
15001i/iX
15003i/iX
3ø
400V range
7.8
13
7.8
26
39
13
200V range
15.6
26
15.6
52
78
26
Note: Constant power mode provides increased current at reduced voltage (See chart below)
Current Limit
Programmable from 0 A to maximum current for selected range
AC+DC Mode Output
Output Power (iX only)
Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20%
3000–15000 VA