beautypg.com

Atec Aeroflex-3920 User Manual

Page 9

background image

For the ver y latest specifications visit

w w w.aeroflex.com

Example of NXDN Tiles

The 3920 NXDN Option supports receiver testing with a variety of
signal generation patterns.

• STD 1031 (1031 Hz pattern)

• STD CAL (1031 Hz pattern with 5% BER)

• STD 511 (PN9 bit sequence)

• STD INTFR (PN15 bit sequence)

ARIB STD T-98 (390XOPT460)

The option provides testing for mobile stations that conform to the
ARIB T-98 standard. This testing is similar to dPMR and NXDN.

TETRA

Mobile station testing with test signal T1 (390XOPT110)

Base station testing with test signal T1 (390XOPT111)

Generate/analyze TETRA RF signals

Base station and mobile station testing plus testing with test
signal T1

Transmit parameter measurements including power, frequency
error, EVM and burst timing

TETRA RF power meter and burst power analysis up to 125 W

Modulation analysis with I/Q constellation and trajectory display

Receiver Bit Error Rate (BER) and Message Error Rate (MER)
measurements

Pass/Fail indication using color coded meters

TETRA protocol analyzer/simulator

Data display mode

Time stamped protocol history

Option for testing Direct Mode Operation (DMO)

Example of TETRA MS Tiles

For TETRA applications, the 3920 is the successor to the Aeroflex
2968 TETRA Radio Test Set, the established industry standard for
TETRA R&D, manufacturing, application development and service
operations. Building upon the experience gained over many years of
TETRA test, the 3920 with the TETRA options provides the world's
best solution for testing TETRA radios. TETRA system options
provide signaling and physical layer measurement requirements for
testing TETRA radio equipment. Measurements are made in
accordance with ETSI EN 300 394-1 for on channel transmitter and
receiver parameters. Signaling functions support TIP (Tetra
Interoperability Profile) compliant TETRA radios, thus ensuring
optimum compatibility with TETRA equipment from various
suppliers. Whatever the device under test, the TETRA system
options have the flexibility to measure the various burst types
specified by the TETRA standard including normal bursts, control
bursts and synchronization bursts. The 3920 offers high speed
measurement capabilities to expedite production testing. As a direct
benefit of high power signal processing capacity, TETRA
measurements are performed nearly nine times faster than its
predecessor.

Profile Full Tile Maximized TETRA