AC POWER REQUIREMENTS

ENVIRONMENTAL/SAFETY

DIMENSIONS AND WEIGHT

GENERAL CHARACTERISTICS

OPTIONAL SYSTEMS

P25 (OPTIONAL)

RF SIGNAL GENERATOR

RF RECEIVER

P25 MEASUREMENTS

MODULATION FIDELITY

Range

0 to 20%

Resolution

0.01%

Accuracy

<5.0% of reading (2.5 to 10%)

SYMBOL DEVIATION

Range

1500 Hz to 2100 Hz

Resolution

0.1 Hz

Accuracy

±10 Hz (1620 to 1980 Hz)

SYMBOL CLOCK ERROR

Range

±1000 mHz

Resolution

0.01 mHz

Accuracy

1 ppm (±48 mHz)

Frequency Range

10 MHz to 1.05 GHz (standard)

(Usable from 100 kHz)

10 MHz to 2.7 GHz

(392XOPT058) (Usable from

100 kHz)

Resolution

1 Hz

Level Range

T/R Port: -10 to +50 dBm

ANT Port: -60.0 to +10 dBm

(with preamp -63)

FREQUENCY

Range

10 MHz to 1.05 GHz

(standard) (Usable from

100 kHz)

10 MHz to 2.7 GHz

(392XOPT058) (Usable from

100 kHz)

Resolution

1 Hz

Accuracy

Frequency standard ±1 count

OUTPUT LEVEL

Range

T/R Port: -130.0 to -40.0 dBm

Gen Port: -130.0 to +0.0 dBm

Resolution

0.1 dB

Accuracy

1.0 dB for levels >-110 dBm

(Typical better than 0.6 dB)

1.5 dB for levels ≤-110 (Typical

better than ±1.0 dB)

Modulation

C4FM, CQPSK, LSM

Test Patterns

STD 1011, STD CAL, STD

SILENCE, STD INTFR, STD

BUSY, STD IDLE, STD 511

(O.153), STORED SPCH, VOICE,

1011, SILENCE

LCD DISPLAY Screen Size

6.4” diagonal

162.6 mm diagonal

Active Area

5.1” (h) x 3.8” (v)

129.6 mm (h) x 97.44 mm (v)

Resolution

640 x 480 pixels

Disk Storage

Internal 30 GByte hard disk

available for user storage

Height

7.75” (19.7 cm)

Width

14” (35.6 cm)

Depth

20.5” (52.0 cm)

Weight

36.8 lbs. (16.5 kg)

LCD Display Screen Size

6.4” diagonal (162.6 mm

diagonal)

OPERATING TEMPERATURE

0 to 50°C (Tested in accordance

with MIL-PRF-28800F Class 3)

WARM-UP TIME

15 minutes

STORAGE TEMPERATURE

-40 to 71°C (Tested in

accordance with MIL-PRF-

28800F Class 3)

RELATIVE HUMIDITY

80% up to 31°C decreasingly

linearly to 50% at 40°C (Tested

in accordance with MIL-PRF-

28800F Class 3)

ALTITUDE

4,000 m (13,123 ft)

(MIL-PRF-28800F Class 3)

SHOCK AND VIBRATIONS

30 G Shock (functional shock)

5-500 Hz random vibrations

(Tested in accordance with

MIL-PRF-28800F Class 3)

USE

Pollution degree 2

EMC

EN 61329, Class A

RELIABILITY

>8,000 hour calculated MTBF

(MIL-HDBK-217F, notice 2)

Safety Standards

UL 61010B-1

EN 61010-1

CSA C22.2 No.61010-1

Voltage

100 V to 120 VAC @ 60 Hz

220 V to 240 VAC @ 50 Hz

Power Consumption

Nominally 120 W (200 W Max)

Mains Supply Voltage Fluctuations

≤10% of the nominal voltage

Fuse Requirements

3 A, 250 V, Type F

18