AUDIO FUNCTION GENERATOR(S)

OSCILLOSCOPE

DIGITAL MULTIMETER

AC/DC VOLTMETER

Full Scale Range

200 mV, 2 V, 20 V, 200 V, 2000 V,

Auto

(150 VAC RMS, or VDC MAX input,

Category II)

Resolution

3-½ digits (2000 counts)

Accuracy

DC ±1% Full Scale ±1 count

AC ±5% Full Scale ±1 count

AC Volts Frequency Range

50 Hz to 20 kHz

AC/DC AMMETER

Full Scale Range

200 mA, 2 A, 20 A, Auto (20 A range

uses optional shunt connected to

Voltmeter)

Maximum Open Circuit

Input Voltage

30 Vrms referenced to common or
earth ground, Category I

Resolution

3-½ digits (2000 counts)

Accuracy

±5% Full Scale ±1 count

AC Volts Frequency Range

50 Hz to 10 kHz

OHMMETER

Full Scale Range

200 ohms, 2 kohms, 20 kohms, 200
kohms, 2 Mohms, 20 Mohms, Auto

Resolution

3 ½ digits (2000 counts)

Accuracy

±5% Full Scale ±1 count

EXTERNAL CURRENT SHUNT
(OPTIONAL)

Rating (Catergory I)

10 amps, 100 mV

20 amps - ON 1 minute, OFF 4
minutes

Accuracy (18

O

to 28

O

C)

DC to 10 kHz: ±0.25%

Temperature Coefficient

0.005%/

o

C

Input Range

0 to 100 Vpeak Max, Category II

Scales

2 mV to 20 V/division in a 1, 2, 5

sequence (8[h] x 10 [w] graticule

display)

Accuracy

5% of full scale (DC to 1 MHz)

10% of full scale (1 to 4 MHz)

Resolution

Better than 1% of full scale

Coupling

DC, AC, GND

HORIZONTAL

Sweep Factors

1 μSec to 1 Sec/division in a 1, 2, 5

sequence

Accuracy

>1.5% of full scale

Resolution

>1% of full scale

Input Impedance

1 M

Ω

, 20 pF

TRIGGER

Trigger Source

Trace A, Trace B, EXT, (or Trace C with no

CH1 or CH2 Input)

Trigger Edge

Rising/falling

Trigger Mode

Auto/normal

Continuous/single shot

External Trigger Level

Hi-Z BNC input on the rear panel of the

unit

Adjustable from -5 to +5 V

DISPLAY

Traces

2

Trace Types

Live, captured, accumulated

Markers

2

Marker Functions

Time with amplitude, deviation or

% depth

Delta marker (including 1/

Δ

t,

e.g. Hz)

VERTICAL

3 dB Bandwidth

16 MHz

Frequency Range

DC to 4 MHz (40 MS/s

sampling rate)

WAVE SHAPE

Sine, Square, Triangle, Ramp, Digital Coded Squelch,
DTMF

FREQUENCY

Range

Sine: 20 Hz to 40 kHz (usable 1 Hz to 40 kHz)

Square, Triangle and Ramp: 20 Hz to 4 kHz (usable

1 Hz to 40 kHz)

Resolution

0.1 Hz

Accuracy

±50 ppm, ±10 ppm typical

LEVEL

Range

1 mV to 5V RMS into a 10 k

Ω

load

Resolution

0.1 mV

Accuracy

±1% of setting (10 k

Ω

load)

Impedance

<10

Ω

Spectral

Purity

<0.5% (1 kHz, 5 Vrms, 80 kHz BW, 10 k

Ω

load,

Sine)

<1.0% (Typical, 20 Hz to 20 kHz, 100 mV to 5 Vrms,
80 kHz BW, 10 k

Ω

load, Sine)

AUDIO FILTERS (CHARACTERISTIC RESPONSE)

Filter

Type

Ripple

-1 dB

-60 dB

NONE

No
Filter

300 Hz

Low-
Pass

<0.23 dB, above
20 Hz

330 Hz

590 Hz

5 kHz

Low-
Pass

<0.02 dB, above
20 Hz

5.5 kHz

6.7 kHz

15 kHz

Low-
Pass

<0.01 dB, above
20 Hz

16.1 kHz

17.8 kHz

20 kHz

Low-
Pass

<0.01 dB, above
20 Hz

20.4 kHz

21 kHz

0.3 to
3.4 kHz

Band-
Pass

<1.7 dB

320 Hz/
3.8 kHz

60 Hz/
5.2 kHz

0.3 to
5 kHz

Band-
Pass

<1.7 dB

320 Hz/
5.2 kHz

60 Hz/
9.6 kHz

0.3 to
15 kHz

Band-
Pass

<1.7 dB

320 Hz/
16.1 kHz

60 Hz/
19.9 kHz

0.3 to
20 kHz

Band-
Pass

<1.7 dB

200 Hz/
20.4 kHz

60 Hz/
21 kHz

PSOPH
C-MSG

Band-
Pass

Per C-MSG Spec

Per C-MSG
Spec

Per C-MSG
Spec

PSOPH
CCITT

Band-
Pass

Per CCITT Spec

Per CCITT
Spec

Per CCITT
Spec

300 Hz

High-
Pass

<1.7 dB

320 Hz

60 Hz

15