Table Q —
Electrical Specifications
Parameter
Value
Input
Voltage (nominal), Vac
120 or 230 (optional 220).
Frequency, Hz, ±5%
60/50 (auto-frequency).
Current, A
2.0 @ 120Vac
1.0 @ 220/230Vac
Input circuit breaker
3.0A, 125Vac
1.5A, 230Vac
Output
Voltage (nominal), Vac
Auxiliary, Vac
120 or 230 ± 10%
24, –5% to +20%
Frequency, Hz, ±5%
60/50 (auto-frequency).
Current, A
4.20 @ 24Vac
0.83 @ 120Vac
0.43 @ 230Vac
Power, W/VA 100 total including auxiliary output
Waveform
Sine wave
Load Crest Factor
3:1 (load dependent)
Output Voltage Distortion
< 3% THD (resistive load)
Efficiency
Normal Mode
Backup (Inverter) Mode
> 85%
> 75%
Transfer Time, ms
AVR to Backup
Backup to AVR
5 (Typical)
3 (Typical)
Line Qualification Time, s 3
Battery String Voltage
24
Battery Charger Current
(Factory default, A)
3
Battery Charger Temperature
Compensation
-5mV / °C / Cell (factory default), user adjustable to -2.5, -4, -5 and -6mV / °C / Cell
via RS-232 connection.
Battery size
Standard: 4 x 9 AHr
Other
Battery circuit breaker
15A
- AlphaCell GelCell Series (32 pages)
- FXM 650, 1100, 2000 UPS (96 pages)
- Cordex 48-1.2kW (68 pages)
- Radium MiniBay (57 pages)
- Fiber Backhaul Enclosure (FBE) (19 pages)
- FBE2322 Enclosure System (38 pages)
- FlexNet PMR, GMR Series (49 pages)
- Te25xh (38 pages)
- FlexNet MPS48-12M - Technical Manual (33 pages)
- FlexNet MPS48-12M - Quick Start Guide (2 pages)
- FlexNet ELPM 300-48D (25 pages)
- FlexNet FMPS (40 pages)
- FlexPoint AX Series (34 pages)
- FlexPoint FPR1207-F - Technical Manual (18 pages)
- FlexPoint FPR1207-F - Quick Start Guide (2 pages)
- AlphaGen PN-6x-T 7.5kW 48VDC - Installation and Operation Manual (79 pages)
- AlphaGen CE-3x2 5K-T 48Vdc (95 pages)
- AlphaGen PN-6x-T 7.5kW 48Vdc (95 pages)
- AlphaGen 3.5_5.0kW Kohler COM5 (80 pages)
- Security Bar Field For UPE-3, UPE-6, UPE-M3, UPE-M6, PN Series and CE Series (2 pages)
- AMPS80 HP (116 pages)
- 255A Bypass Switch (24 pages)
- AMP24 HP (108 pages)
- FXM350_Micro350 UPS (112 pages)
- CFR 600, CFR 600XT, CFR 1000 (70 pages)
- BPS Series Bypass Switch (36 pages)
- CFR Intelligent Interface Device (54 pages)
- CFR Redundant Control Unit (23 pages)
- CFR 5000, CFR 5000RM (88 pages)
- CFR 3000, CFR 3000RM (86 pages)
- CFR 1500, CFR 1500RM (83 pages)
- CFR 1500, CFR 2000, CFR 2500, CFR 3000 (76 pages)
- Continuity: 1000_2000_3000 (48 pages)
- Continuity Battery Pack (20 pages)
- Continuity: 6K_10K (52 pages)
- Micro, Micro XL, Micro XL3 UPS (99 pages)
- Te17 (32 pages)
- Te45 (68 pages)
- Te41, 48V (76 pages)
- Te41, 24V (72 pages)
- Te43 (60 pages)
- AlphaGuard AG-CMT Installation (2 pages)
- AlphaGuard AG-CMT-3SC_4SC-P (2 pages)
- Digital Midtron DM-3200 AT (2 pages)