X143IP Intermediate Power Generator

Quick Start Instructions

Attaining Optimal Performance

• For optimum functioning of the X143IP Power Generator, the AC voltage of the turbine should be

between 185 and 200 VAC

• If the AC voltage is lower, please refer to the chart below see (Figure 8) to find your differential

pressure across the turbine

• This differential pressure allows you to know the maximum power delivered from the X143IP Power

Generator. With this information, you can evaluate power generated versus power consumed

40

60

80

100

120

140

160

180

200

220

AC volta

ge [VAC]

Differential pressure across the turbine (psi)

Differential Pressure across the Cla-Val Automatic Control Valve (psi)

21

18

15

12

9

6

3

0

1.5

2.9

4.4

5.8

7.3

8.7

10.2

11.6 13.1

14.5

0.0

0.2

0.5

0.7

1.0

1.2

1.5

1.7

Power (w)

Current (A)

1.42 2.84 4.27 5.69 7.11 8.53 9.95

Output

Voltage

Amp Continuous

(60 min/h)

Amps Low Peak

(10 min/h)

Amps High Peak

(1 min/h)

12 V

1.2 A
14 W

3 A

36 W

5 A

60 W

24 V

(step-up)

0.6 A
14 W

1.5 A

36 W

2.5 A

60 W

Figure 8 Differential Pressure Across X143IP Turbine

Typical Installations: Underground Vault/Pressure Reducing Stations