Wiring Instructions

IMPORTANT SAFETY PRECAUTION

Before making any wiring connections in the electrical box,

please take the following precautions:

• Ensure that the isolation valve on the bypass is closed

so that the turbine cannot be engaged

• Confirm that the battery is disconnected
• Confirm that the LED on the PCB is not blinking

• Terminal 1: +12 VDC; Terminal 2: 0V
• Terminal 3: +24 VDC; Terminal 4: 0V
• Terminal 5 and Terminal 6: Alarm battery (dry contact relay closure)

Figure 3:

The removable terminal strip with

Terminals 1 - 10 makes

connections easier

Figure 1: X143IP

Figure 2: Terminal Connections

X143IP Intermediate Power Generator

Quick Start Instructions

2

Make electrical

connections as shown

in Figure 2.