beautypg.com

Cla-Val 61-02/661-02 Technical Manual User Manual

Page 17

background image

Model 100-21

Flow Chart

(Based on normal flow through a wide open valve)

K =

894d

4

C

2

v

L =

K

12 f

K Factor (Resistance Coefficient)
The Value of K is calculated from the formula:
(U.S. system units)

Equivalent Length of Pipe
Equivalent lengths of pipe (L) are determined from the formula:
(U.S. system units)

Fluid Velocity
Fluid velocity can be calculated from the following formula:
(U.S. system units)

d

V =

.4085 Q

2

d

C

V

Factor

Formulas for computing C Factor, Flow (Q) and Pressure Drop

V

( P):

C

V

=

Q

P

C

V

=

Q

P

C

V

=

Q

P

2

V

Where:

U.S. (gpm) @ 1 psi differential at 60 F water

(l/s) @ 1 bar (14.5 PSIG) differential

or

at 15 C water

inside pipe diameter of Schedule 40 Steel Pipe (inches)

friction factor for clean, new Schedule 40 pipe

(dimensionless) (from Cameron Hydraulic Data,

18th Edition, P 3-119)

Resistance Coefficient (calculated)

Equivalent Length of Pipe (feet)

Flow Rate in U.S. (gpm) or (l/s)

Fluid Velocity (feet per second) or (meters per second)

Pressure Drop in (psi) or (bar)

=

=

=

=

=

=

=

=

=

P

V

Q

L

K

f

d

C

3

80

62

15

293

89.3

20.6

.032

.12

4

100

136

32.5

135

32

251

76.4

254

77.6

12.7

12.9

.08

.30

6

150

229

55

233

56

777

237.1

751

229

23.1

22.3

.17

.64

8

200

480

115

545

132

748

228.1

580

176.9

15.7

12.2

.53

2.0

10

250

930

223

621

189.5

10.4

1.26

4.8

12

300

1458

350

654

199.4

8.5

2.51

9.5

14

350

1725

414

750

228.7

8.9

4

15.1

16

400

2110

506

977

298.1

10.2

4

15.1

18

460

2940

705

983

299.9

8.4

9.6

36.2

20

510

3400*

816

1125

343.2

8.8

9.6

36.2

24

610

3500*

840

3005

916.6

19.1

9.6

36.2

30

750

7900*

1895

2130

649.6

10.5

29.0

110

Globe

Pattern

Angle

Pattern

Globe

Pattern

Angle

Pattern

Equivalent

Length

of

Pipe

C

V

Factor

Functional Data

Model 100-21

*Estimated

Valve Size

Liquid Displaced

from Diaphragm

Chamber When

Valve Opens

K

Factor

mm.

Gal./Min. (gpm.)

Litres/Sec. (l/s.)

Gal./Min. (gpm.)

Litres/Sec. (l/s.)

Feet (ft.)

Meters (m.)

Feet (ft.)

Meters (m.)

Fl. Oz

U.S. Gal.

ml

Litres

Inches

Globe Pattern

Angle Pattern