6” sqfw square lensed wallwash – Gotham 6 SQFW Square Lensed Wallwash SpecSheet User Manual
Page 3
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 03/06/14. Specifications subject to change without notice.
PAGE 3 OF 3
SQFW-6-LENSED
PH
OTO
M
ET
RY
6” SQFW
Square Lensed Wallwash
Double Twin-Tube or Triple-Tube lamp
Fixture/Lamp
Candlepower Data
Footcandle values
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
room
wall
90
0
112
0
1 2
135
0
157
0
1 2
67
0
1 2
45
0
22
0
1 2
SQFW 1/32TRT 6AR
CF32DT/E/IN/835 lamp
2400 rated lumens
Test No. LTL16134
P lane Angle
R oom S ide W all S ide
V ertical Angle
R oom
157.5°
135°
112.5°
90°
67.5°
45°
22.5° W all
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
638
612
569
468
342
215
126
71
4
1
0
638
615
576
492
367
233
125
47
5
1
0
638
623
576
516
369
218
102
29
5
1
0
638
633
589
488
336
186
80
26
4
1
0
638
645
616
491
315
171
74
27
6
1
0
638
663
665
557
363
185
95
43
11
1
0
638
678
718
669
501
308
146
67
22
1
0
638
686
755
741
613
412
270
149
50
0
0
638
684
752
731
591
423
302
201
74
0
0
3 ft. from wall
3 ft. from wall
on 3 ft. centers
on 4 ft. centers
1
2
3
4
5
6
7
8
9
10
13
23
23
21
18
15
12
10
8
6
7
18
22
21
19
15
12
10
8
6
13
23
23
21
18
15
12
10
8
6
12
20
20
17
14
11
9
7
6
5
4
11
15
15
14
11
9
7
6
5
12
20
20
17
14
11
9
7
6
5
SQFW 1/42TRT 6AR
CF42DT/E/IN/835 lamp
3200 rated lumens
Test No. LTL16136
P lane Angle
R oom S ide W all S ide
V ertical Angle
R oom 157.5°
135°
112.5°
90° 67.5° 45° 22.5° W all
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
718
684
639
534
385
249
148
83
4
1
0
718
693
649
553
398
248
136
52
5
1
0
718
700
637
538
378
222
107
33
5
1
0
718
709
627
495
339
189
85
29
5
1
0
718
721
642
488
310
177
81
30
7
1
0
718
739
688
542
352
186
100
48
12
1
0
718
751
758
660
481
288
137
71
24
1
0
718
759
823
784
611
395
256
146
47
0
0
718
757
828
808
647
468
340
232
84
0
0
3 ft. from wall
3 ft. from wall
on 3 ft. centers
on 4 ft. centers
1
2
3
4
5
6
7
8
9
10
14
25
25
23
20
16
13
11
9
7
8
20
23
23
20
16
13
11
9
7
14
25
25
23
20
16
13
11
9
7
13
23
22
19
16
13
10
8
7
5
4
12
16
16
15
12
10
8
7
5
13
23
21
19
16
13
10
8
7
5
SQFW 1/32TRT 6DSR
CF32DT/E/IN/835 lamp
2400 rated lumens
Test No. LTL16135
P lane Angle
R oom S ide W all S ide
V ertical Angle
R oom 157.5°
135°
112.5°
90° 67.5° 45° 22.5° W all
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
522
490
430
365
320
237
123
73
58
9
0
522
493
446
389
343
268
147
70
38
7
0
522
505
468
413
319
220
121
46
20
5
0
522
520
500
415
289
171
88
36
12
4
0
522
536
543
444
292
167
86
39
13
3
0
522
555
607
534
363
190
103
58
23
4
0
522
570
658
641
490
310
159
79
33
4
0
522
580
677
695
595
422
287
162
61
4
0
522
578
662
656
543
410
304
202
82
6
0
3 ft. from wall
3 ft. from wall
on 3 ft. centers
on 4 ft. centers
1
2
3
4
5
6
7
8
9
10
14
24
24
21
18
14
11
9
7
6
9
20
23
21
18
14
11
9
7
6
14
24
24
21
18
14
11
9
7
6
13
21
20
17
14
11
9
7
6
5
5
13
16
15
13
11
9
7
6
5
13
21
20
17
14
11
9
7
6
5
SQFW 1/42TRT 6DSR
CF42DT/E/IN/835 lamp
3200 rated lumens
Test No. LTL16137
P lane Angle
R oom S ide W all S ide
V ertical Angle
R oom 157.5°
135°
112.5°
90° 67.5° 45° 22.5° W all
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
608
570
504
441
376
273
136
85
68
9
0
608
572
510
450
381
276
143
70
39
7
0
608
581
521
435
330
224
125
51
23
5
0
608
595
538
418
292
180
97
41
13
4
0
608
613
569
441
290
179
97
44
14
3
0
608
633
637
522
355
197
115
66
25
4
0
608
653
707
640
479
302
159
89
39
4
0
608
665
755
751
602
412
279
165
62
5
0
608
667
758
756
618
470
351
241
97
7
0
3 ft. from wall
3 ft. from wall
on 3 ft. centers
on 4 ft. centers
1
2
3
4
5
6
7
8
9
10
16
27
27
24
20
16
13
10
8
7
10
23
25
24
20
16
13
10
8
7
16
27
27
24
20
16
13
10
8
7
15
24
22
19
15
12
10
8
6
5
6
14
17
17
15
12
10
8
6
5
15
24
22
19
15
12
10
8
6
5
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.