11” cf wallwash cylinders, Fixture/lamp candlepower data footcandle values – Gotham 11 CF Wallwash Cylinders SpecSheet User Manual

Page 3

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2003-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/19/13. Specifications subject to change without notice.

PAGE 3 OF 3

CF11-8-WALLWASh

PH

OTO
M

ET

RY

11” CF

Wallwash Cylinders

Horizontal Lamp, Double Twin-Tube or Triple-Tube, 8” Aperture

Fixture/Lamp

Candlepower Data

Footcandle values

TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.

room

wall

90

0

112

0

1 2

135

0

157

0

1 2

67

0

1 2

45

0

22

0

1 2

CF11 1/26TRT 8ARW

(1) PL-T 26W 4PIN lamp

1800 total rated lumens

Test No. LTL17623

Plane Angle

Wall 22.5

45

67.5

90 112.5 135 157.5

0

5

15

25

35

45

55

65

75

85

90

715

789

587

480

347

181

105

61

33

8

0

715

809

637

511

383

207

106

59

31

8

0

715

818

683

523

396

223

92

51

26

6

0

715

806

692

510

369

205

82

39

18

5

0

715

783

689

483

327

160

66

25

11

2

0

715

748

678

458

326

177

46

13

5

1

0

715

712

648

443

345

185

32

4

1

0

0

715

674

595

441

345

146

29

2

1

0

0

Vertical Angle

Wallwash Illuminance Study (fc)

Illuminance on wall from 6 luminaires

Luminaire

mounted 3 ft.

from wall

Luminaire

mounted 3 ft.

from wall

Luminaire

mounted 3 ft.

from wall

3 ft. between

luminaires

4 ft. between

luminaires

5 ft. between

luminaires

ft. from ceiling

3 3.5 4

3 3.5 4

3 3.5 4

1

2

3

4

5

6

7

8

9

10

11

12

6

9

12

13

12

11

9

7

6

5

4

4

5

9

11

13

12

10

9

7

6

5

4

4

6

9

12

13

12

11

9

7

6

5

4

3

5

8

9

10

9

8

7

6

5

4

3

3

3

6

8

9

9

8

7

6

5

4

3

3

5

8

9

10

9

8

7

6

5

4

3

3

4

7

8

9

8

7

5

5

4

3

3

2

2

4

6

7

7

6

5

4

4

3

3

2

4

7

8

9

8

7

5

5

4

3

3

2

CF11 1/32TRT 8ARW

(1) PL-T 32W 4PIN lamp

2400 total rated lumens

Test No. LTL17625

Plane Angle

Wall 22.5

45

67.5

90 112.5 135 157.5

0

5

15

25

35

45

55

65

75

85

90

1183

1170

818

667

477

248

141

82

44

10

0

1183

1174

860

691

506

277

140

79

41

10

0

1183

1149

886

686

500

282

121

67

34

8

0

1183

1110

875

652

445

250

106

50

24

6

0

1183

1062

866

613

389

199

84

32

14

3

0

1183

1017

867

592

401

226

59

16

6

1

0

1183

988

853

586

443

235

43

5

2

1

0

1183

966

794

596

457

194

41

2

1

1

0

Vertical Angl

e

Wallwash Illuminance Study (fc)

Illuminance on wall from 6 luminaires

Luminaire

mounted 3 ft.

from wall

Luminaire

mounted 3 ft.

from wall

Luminaire

mounted 3 ft.

from wall

3 ft. between

luminaires

4 ft. between

luminaires

5 ft. between

luminaires

ft. from ceiling

3 3.5 4

3 3.5 4

3 3.5 4

1

2

3

4

5

6

7

8

9

10

11

12

7

13

16

18

17

14

12

10

8

7

6

5

7

12

15

17

17

14

12

10

8

7

6

5

7

13

16

18

17

14

12

10

8

7

6

5

6

10

13

14

13

11

9

8

6

5

5

4

4

8

11

13

12

11

9

8

6

5

5

4

6

10

13

14

13

11

9

8

6

5

4

4

6

9

11

12

11

9

7

6

5

4

4

3

3

6

8

9

9

9

7

6

5

4

4

3

6

9

11

12

11

9

7

6

5

4

4

3

CF11 1/42TRT 8ARW

(1) PL-T 42W 4PIN lamp

3200 total rated lumens

Test No. LTL17627

Plane Angle

Wall 22.5

45

67.5

90 112.5 135 157.5

0

5

15

25

35

45

55

65

75

85

90

1408

1437

1079

892

628

325

186

108

58

13

0

1408

1441

1112

887

644

349

182

103

54

13

0

1408

1415

1117

848

609

346

156

86

43

11

0

1408

1370

1080

778

526

296

133

63

30

8

0

1408

1326

1067

730

461

240

104

40

17

4

0

1408

1299

1088

732

490

274

71

19

7

1

0

1408

1291

1096

756

554

277

52

5

2

1

0

1408

1281

1046

788

578

234

52

2

1

0

0

Vertical Angl

e

Wallwash Illuminance Study (fc)

Illuminance on wall from 6 luminaires

Luminaire

mounted 3 ft.

from wall

Luminaire

mounted 3 ft.

from wall

Luminaire

mounted 3 ft.

from wall

3 ft. between

luminaires

4 ft. between

luminaires

5 ft. between

luminaires

ft. from ceiling

3 3.5 4

3 3.5 4

3 3.5 4

1

2

3

4

5

6

7

8

9

10

11

12

10

17

21

24

22

19

16

13

11

9

7

6

9

15

20

23

22

19

16

13

11

9

8

6

10

17

21

24

22

19

16

13

11

9

7

6

8

14

16

19

17

15

12

10

8

7

6

5

6

10

14

16

16

14

12

10

8

7

6

5

8

14

16

19

17

15

12

10

8

7

6

5

8

12

15

16

15

12

10

8

7

6

5

4

4

7

10

12

12

11

10

8

7

6

5

4

8

12

15

16

15

12

10

8

7

6

5

4

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.