8” cfv wallwash cylinders, Fixture/lamp candlepower data footcandle values – Gotham 8 CFV Wallwash Cylinders SpecSheet User Manual
Page 4

© 2003-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/19/13. Specifications subject to change without notice.
PAGE 4 OF 4
CFV-8-WALLWASH
PH
OTO
M
ET
RY
8” CFV
Wallwash Cylinders
Vertical Lamp, Double Twin-Tube or Triple-Tube, 6” Aperture
Fixture/Lamp
Candlepower Data
Footcandle values
room
wall
90
0
112
0
1 2
135
0
157
0
1 2
67
0
1 2
45
0
22
0
1 2
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
CFV8 42TRT 6ARW
(1) PL-T 42W 4PIN lamp
3200 rated lumens
Test No. LTL17608
Plane Angle
Wall 22.5
45
67.5
90 112.5 135 157.5
0
5
15
25
35
45
55
65
75
85
90
909
934
831
635
438
262
154
91
43
9
0
909
931
836
642
431
255
148
84
39
7
0
909
924
821
626
418
239
131
70
31
5
0
909
914
800
608
400
220
109
52
21
3
0
909
903
793
600
384
202
86
32
12
1
0
909
893
797
595
366
181
60
15
5
1
0
909
884
785
594
348
162
36
4
1
0
0
909
882
770
576
335
147
23
1
1
0
0
Vertical Angle
Wallwash Illuminance Study (fc)
Illuminance on wall from 6 luminaires
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
3 ft. between
luminaires
4 ft. between
luminaires
5 ft. between
luminaires
ft. from ceiling
3 3.5 4
3 3.5 4
3 3.5 4
1
2
3
4
5
6
7
8
9
10
11
12
7
14
17
17
16
14
12
10
8
7
6
5
6
13
16
17
16
14
12
10
8
7
6
5
7
14
17
17
16
14
12
10
8
7
6
5
6
11
13
14
12
11
9
8
6
5
5
4
4
9
11
12
12
10
9
8
6
5
5
4
6
11
13
14
12
11
9
8
6
5
5
4
6
10
12
12
10
9
7
6
5
4
4
3
3
6
8
9
9
8
7
6
5
4
4
3
6
10
12
12
10
9
7
6
5
4
4
3
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.