9” cfv wallwash cylinders, Fixture/lamp candlepower data footcandle values – Gotham 9 CFV Wallwash Cylinders SpecSheet User Manual
Page 3

© 2003-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/19/13. Specifications subject to change without notice.
PAGE 3 OF 4
CFV-9-WALLWASH
PH
OTO
M
ET
RY
9” CFV
Wallwash Cylinders
Vertical Lamp, Double Twin-Tube or Triple-Tube, 8” Aperture
Fixture/Lamp
Candlepower Data
Footcandle values
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
room
wall
90
0
112
0
1 2
135
0
157
0
1 2
67
0
1 2
45
0
22
0
1 2
CFV9 18TRT 8ARW
(1) PL-T 18W 4PIN lamp
1200 total rated lumens
Test No. LTL17612
Plane Angle
Wall 22.5
45
67.5
90 112.5 135 157.5
0
5
15
25
35
45
55
65
75
85
90
583
615
474
354
251
136
76
46
23
6
0
583
604
461
338
243
137
75
45
22
6
0
583
586
441
335
240
131
71
39
19
5
0
583
554
422
334
233
119
61
30
13
4
0
583
519
408
320
220
107
49
19
8
2
0
583
506
400
305
203
94
35
9
3
1
0
583
504
395
307
198
82
22
3
1
0
0
583
510
389
310
192
71
13
1
0
0
0
Vertical Angle
Wallwash Illuminance Study (fc)
Illuminance on wall from 6 luminaires
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
3 ft. between
luminaires
4 ft. between
luminaires
5 ft. between
luminaires
ft. from ceiling
3 3.5 4
3 3.5 4
3 3.5 4
1
2
3
4
5
6
7
8
9
10
11
12
4
7
9
9
9
8
6
5
5
4
3
3
4
7
8
9
9
8
6
5
5
4
3
3
4
7
9
9
9
8
6
5
5
4
3
3
3
6
7
7
7
6
5
4
4
3
3
2
2
5
6
7
7
6
5
4
3
3
3
2
3
6
7
7
7
6
5
4
4
3
3
2
3
5
6
7
6
5
4
3
3
2
2
2
2
3
4
5
5
5
4
3
3
2
2
2
3
5
6
7
6
5
4
3
3
2
2
2
CFV9 26TRT 8ARW
(1) PL-T 26W 4PIN lamp
1800 total rated lumens
Test No. LTL17614
Plane Angle
Wall 22.5
45
67.5
90 112.5 135 157.5
0
5
15
25
35
45
55
65
75
85
90
871
928
740
541
366
196
107
64
32
7
0
871
917
738
555
373
192
105
61
29
6
0
871
889
709
547
361
180
95
51
23
5
0
871
858
675
517
338
163
80
38
16
3
0
871
823
641
478
313
147
63
24
9
1
0
871
798
623
473
301
132
46
12
4
1
0
871
777
610
466
287
118
30
4
1
0
0
871
762
597
462
277
107
20
1
1
0
0
Vertical Angle
Wallwash Illuminance Study (fc)
Illuminance on wall from 6 luminaires
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
3 ft. between
luminaires
4 ft. between
luminaires
5 ft. between
luminaires
ft. from ceiling
3 3.5 4
3 3.5 4
3 3.5 4
1
2
3
4
5
6
7
8
9
10
11
12
6
10
12
14
13
12
10
8
7
6
5
4
5
9
11
13
13
12
10
8
7
6
5
4
6
10
12
14
13
12
10
8
7
6
5
4
5
8
10
11
10
9
8
6
5
5
4
3
3
6
8
10
10
9
8
6
5
5
4
3
5
8
10
11
10
9
8
6
5
5
4
3
4
7
9
10
8
7
6
5
4
4
3
3
2
4
6
7
7
7
6
5
4
4
3
3
4
7
9
10
8
7
6
5
4
4
3
3
CFV9 32TRT 8ARW
(1) PL-T 32W 4PIN lamp
2400 total rated lumens
Test No. LTL17615
Plane Angle
Wall 22.5
45
67.5
90 112.5 135 157.5
0
5
15
25
35
45
55
65
75
85
90
1135
1102
854
614
432
257
137
83
42
12
0
1135
1072
840
624
436
244
132
76
37
9
0
1135
1047
801
608
411
221
115
61
28
6
0
1135
1018
757
567
377
197
93
43
18
3
0
1135
999
726
533
350
172
70
24
9
1
0
1135
987
713
526
330
149
46
10
3
0
0
1135
984
703
524
314
129
26
2
1
0
0
1135
990
691
518
303
119
19
1
0
0
0
Vertical Angl
e
Wallwash Illuminance Study (fc)
Illuminance on wall from 6 luminaires
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 3 ft.
from wall
3 ft. between
luminaires
4 ft. between
luminaires
5 ft. between
luminaires
ft. from ceiling
3 3.5 4
3 3.5 4
3 3.5 4
1
2
3
4
5
6
7
8
9
10
11
12
7
13
16
17
16
14
12
10
8
7
6
5
6
12
15
17
16
14
12
10
8
7
6
5
7
13
16
17
16
14
12
10
8
7
6
5
6
10
13
13
12
10
9
8
6
5
5
4
4
8
10
12
12
10
9
7
6
5
5
4
6
10
13
13
12
10
9
8
6
5
5
4
6
9
12
11
10
8
7
6
5
4
4
3
3
6
7
9
9
8
7
6
5
4
4
3
6
9
12
11
10
8
7
6
5
4
4
3
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.