beautypg.com

Pdrdf 6wg, Pdrdf 6ag, Pdrdf 6bg – Gotham 6 PDRDF Recessed Dish_Glass Shade SpecSheet User Manual

Page 3: 6” pdrdf recessed dish/glass shade

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2011-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/05/13. Specifications subject to change without notice.

PAGE 3 OF 3

PDRDF-6-OPEn

PDRDF 6WG

18TRT white glass, 1200 rated lumens, 1.2 s/mh, Test No. LTL19783

PDRDF 6AG

26TRT amber glass, 1800 rated lumens, 1.2 s/mh, Test No. LTL19779

PDRDF 6BG

32TRT blue glass, 2400 rated lumens, 1.3 s/mh, Test No. LTL19778

PH

OTO
M

ET

RY

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

6” PDRDF

Recessed Dish/Glass Shade

Triple-Tube and Double Twin-Tube Lamps

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.

20°

40°

60°

80°

Ave Lumens

0

5

15

25

35

45

55

65

75

85

90

247

250

258

232

176

136

100

61

32

12

5

24

72

106

110

105

89

61

34

14

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

202.4

312.8

506.6

615.4

0.0

615.4

16.9

26.1

42.2

51.3

0.0

*51.3

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

61

54

47

42

37

34

30

28

25

23

22

61

52

44

38

33

29

26

23

21

19

18

61

50

41

35

30

26

23

20

18

17

15

60

53

46

41

37

33

30

27

25

23

21

60

51

43

37

33

29

26

23

21

19

18

60

49

41

34

30

26

23

20

18

17

15

57

50

44

40

35

32

29

27

24

23

21

57

49

42

36

32

28

25

23

21

19

17

57

47

40

34

29

26

23

20

18

16

15

RCR

50% beam -

62.5°

10% beam -

105.0°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

8.2

4.4

2.7

1.9

1.4

6.7

9.1

11.5

14.0

16.4

4.1

2.2

1.4

0.9

0.7

14.3

19.5

24.8

30.0

35.2

0.8

0.4

0.3

0.2

0.1

10°

20°

30°

40°

50°

60°

70°

80°

90°

100

200

20°

40°

60°

80°

Ave Lumens

0

5

15

25

35

45

55

65

75

85

90

325

334

358

338

262

169

101

57

27

7

0

32

101

154

163

131

91

57

29

8

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

287.7

450.8

673.0

767.5

0.3

0.5

2.3

3.4

770.9

12.0

18.8

28.0

32.0

0.0

0.0

0.1

0.1

*32.1

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

38

34

30

27

24

22

20

18

17

16

15

38

33

28

25

22

20

18

16

14

13

12

38

32

27

23

20

18

16

14

13

12

11

37

33

30

27

24

22

20

18

17

15

14

37

32

28

25

22

19

17

16

14

13

12

37

31

27

23

20

18

16

14

13

11

11

36

32

29

26

23

21

19

18

16

15

14

36

31

27

24

21

19

17

15

14

13

12

36

30

26

22

20

17

15

14

13

11

10

RCR

50% beam -

66.0°

10% beam -

100.8°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

10.9

5.8

3.6

2.5

1.8

7.1

9.7

12.3

14.9

17.5

5.4

2.9

1.8

1.2

0.9

13.3

18.1

23.0

27.8

32.6

1.1

0.6

0.4

0.2

0.2

10°

20°

30°

40°

50°

60°

70°

80°

90°

100

200

300

20°

40°

60°

80°

Ave Lumens

0

5

15

25

35

45

55

65

75

85

90

210

215

235

206

139

79

48

26

13

4

1

21

66

94

86

62

43

26

14

4

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

180.9

267.1

371.8

416.0

0.1

0.3

1.8

2.7

418.8

10.1

14.8

20.7

23.1

0.0

0.0

0.1

0.2

*23.3

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

28

25

22

20

18

17

15

14

13

12

11

28

24

21

18

16

15

13

12

11

10

09

28

23

20

17

15

13

12

11

10

09

08

27

24

22

20

18

16

15

14

13

12

11

27

24

21

18

16

15

13

12

11

10

09

27

23

20

17

15

13

12

11

10

09

08

26

23

21

19

17

16

15

13

12

12

11

26

23

20

18

16

14

13

12

11

10

09

26

22

19

17

15

13

12

11

10

09

08

RCR

50% beam -

61.7°

10% beam -

95.5°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

7.0

3.7

2.3

1.6

1.2

6.6

9.0

11.4

13.8

16.1

3.5

1.9

1.2

0.8

0.6

12.1

16.5

20.9

25.3

29.7

0.7

0.4

0.2

0.2

0.1

10°

20°

30°

40°

50°

60°

70°

80°

90°

100

200