Pdxf 2/32trt 8ar wlrr, Pdxf 2/32trt 8ar wlrf, 8” pdxf ice™ color – Gotham 8 PDXF Ice Color SpecSheet User Manual
Page 3
![background image](/manuals/312848/3/background.png)
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/09/13. Specifications subject to change without notice.
PAGE 3 OF 3
PDXF-8-COLOR
PDXF 2/32TRT 8AR WLRR
(2) CF32DT/E/IN/835, 2400 lumens per lamp, Test no. LTL14261X
PDXF 2/32TRT 8AR WLRF
(2) CF32DT/E/IN/835, 2400 lumens per lamp, Test no. LTL14262X
PH
OTO
M
ET
RY
Distribution Curve
Distribution Data
Output Data
Coefficient of Utilization
Illuminance: Single Luminaire 30” Above Floor
8” PDXF
Ice™ Color
Horizontal Lamp, Triple-Tube
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
Zone Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
722.7
1003.9
1286.0
1365.5
0.0
1365.5
15.1
20.9
26.8
28.4
0.0
*28.4
*E fficiency
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
200
400
600
800
1000
pf
pc
pw
20%
80%
70%
50%
50% 30% 50% 30% 50% 30%
1
2
3
4
5
6
7
8
9
10
.31
.28
.26
.24
.22
.20
.19
.17
.16
.15
.30
.27
.24
.22
.20
.18
.17
.15
.14
.13
.30
.28
.25
.23
.21
.20
.18
.17
.16
.15
.29
.26
.24
.21
.20
.18
.16
.15
.14
.13
.29
.27
.24
.23
.21
.19
.18
.17
.16
.15
.28
.26
.23
.21
.19
.18
.16
.15
.14
.13
From 0°
Ave
Lumens
0
5
15
25
35
45
55
65
75
85
90
1094
1082
998
754
450
229
113
51
19
6
0
102
278
343
281
179
103
52
21
6
50% beam angle
50.8°
10% beam angle
84.9°
Mount
height
Inital fc
at beam
center
Beam
diameter
fc at
beam
edge
Beam
diameter
fc at
beam
edge
8
10
12
14
16
36.2
19.4
12.1
8.3
6.0
5.2
7.1
9.0
10.9
12.8
18.1
9.7
6.1
4.1
3.0
10.1
13.7
17.4
21.0
24.7
3.6
1.9
1.2
0.8
0.6
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
756.1
1064.5
1372.2
1448.6
0.0
1448.6
15.8
22.2
28.6
30.2
0.0
*30.2
*E fficiency
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
200
400
600
800
1000
pf
pc
pw
20%
80%
70%
50%
50% 30% 50% 30% 50% 30%
1
2
3
4
5
6
7
8
9
10
.33
.30
.27
.25
.23
.21
.20
.18
.17
.16
.32
.28
.25
.23
.21
.19
.18
.16
.15
.14
.32
.29
.27
.25
.23
.21
.19
.18
.17
.16
.31
.28
.25
.23
.21
.19
.17
.16
.15
.14
.31
.28
.26
.24
.22
.20
.19
.18
.17
.16
.30
.27
.25
.22
.20
.19
.17
.16
.15
.14
F rom 0°
Ave
Lumens
0
5
15
25
35
45
55
65
75
85
90
1095
1094
1031
803
496
254
120
52
18
3
0
104
288
365
308
198
109
53
20
4
50% beam angle
52.6°
10% beam angle
86.7°
Mount
height
Inital fc
at beam
center
B eam
diameter
fc at
beam
edge
B eam
diameter
fc at
beam
edge
8
10
12
14
16
36.2
19.5
12.1
8.3
6.0
5.4
7.4
9.4
11.4
13.4
18.1
9.7
6.1
4.1
3.0
10.4
14.2
17.9
21.7
25.5
3.6
1.9
1.2
0.8
0.6