Gotham 6 DPH PAR Directional SpecSheet User Manual
6” dph
Luminaire Type:
Catalog Number
(autopopulated):
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 03/04/14. Specifications subject to change without notice.
PAGE 1 OF 3
DPH-6-PAR-DIR
Gotham Architectural Downlighting
HID Downlights
6” DPH
PAR Directional
FE
AT
U
RE
S
OR
DER
ING
IN
FO
RM
AT
ION
OPTICAL SYSTEM
•
Center Beam optical system centers the lamp relative to the aperture, optimiz-
ing lamp efficiency.
•
Tool-less 0° - 40° vertical and 355° horizontal lamp adjustments made with the
trim assembly removed for simple focusing. Lockable adjustment mechanisms
maintain focus during relamping and are visible from below the ceiling with trim
assembly removed.
•
Designed to allow hot aiming.
•
Self-flanged, semi-specular or matte-diffuse cone designed to minimize
backflash. Contour cut reduces visibility of inner housing.
•
Trim assembly retained by self-aligning torsion support springs.
•
Internal housing components painted black.
MECHANICAL SYSTEM
•
Black painted housing features tool-less top access and accommodates a
maximum 1-1/2” ceiling thickness.
•
Re-lamp capability from above or below ceiling.
•
Mounting bars are 16-gauge galvanized steel with continuous 4” vertical adjust-
ment, held in place with tool-less, integral camaction locking. Post installation
adjustment possible without the use of tools from above or below the ceiling.
Shipped pre-installed.
•
Secondary housing adjustment system for precise, final ceiling to flange
alignment.
•
Galvanized steel junction box with bottom-hinged access covers and spring
latches. Two combination 1/2” - 3/4” and three 1/2” knockouts for straight-
through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated
for 90°C.
ELECTRICAL SYSTEM
•
Tool-less access door provides access to junction box through the aperture.
•
Medium base porcelain socket with nickel-plated screw shell.
•
Pre-wired, encased-and-potted, electromagnetic, 120/277V or 120/347V ballast
tray module is standard. Module can be attached before or after mounting of
mounting/plaster frame.
•
Thermally-activated insulation detector is replaceable without the use of tools.
LISTING
•
Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
•
1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
EXAMPLE: DPH P3039MHC 6ACT30 120 TRW
Series Lamp type
1
Wattage/Lamp
Aperture
Trim color
Type
Finish
Voltage
DPH
(blank)
P30
P38
Metal halide
70M
70W PAR38
100M
100W PAR38
150M
2
150W PAR38
Ceramic metal halide
39MHC
39W PAR30
70MHC
70W PAR38 or PAR30
100MHC
100W PAR38
150MHC
2
150W PAR38
6
AC
Clear
BC
3
Black
PC
Pewter
WTC
Wheat
GC
4
Gold
WC
3
White painted
MB
3
Contoured black baffle
WB
3
Contoured white baffle
T30
Cut for angles
25°-40°
T20
Cut for angles
15°-25°
T00
Cut for angles
0°-15°
(blank)
Semi-specular
LD
Matte-diffuse
LS
Specular
120
277
347
Ballast
Options
(blank) Electro-magnetic
ballast
HEB
5
Electronic
ballast
TRW
White painted flange (standard with WC, MB and WB)
RRL
6
RELOC
®
-ready luminaire. Provides compatibility with Lithonia
RELOC system. Access above ceiling required.
QRS
7
Quartz restrike system (uses 100W max. DC base quartz lamp
by others)
QRSTD
7
Quartz restrike system with time delay
SF
Single fuse
EC
7
Emergency circuit (DC socket with leads for connection
to external emergency power source; 100W max. lamp)
CP
Chicago plenum
LPFL
Flood lamp (shipped separately)
LPSP
Spot lamp (shipped separately)
LPWFL
8
Wide flood lamp (shipped separately)
ACCESSORIES order as separate catalog numbers (shipped separately)
LFH502
Locking filter holder for all lamp types.
F500
9
Lens for use with 500 series filter holder
LTWFH500 DBL
Filter holder for use with PAR30 lamps
F700
9
Lens for use with 700 series filter holder
LTWFH700 DBL
Filter holder for use with PAR38 lamps