Gotham 8 DPH PAR Directional SpecSheet User Manual
8” dph
Luminaire Type:
Catalog Number
(autopopulated):
© 2007-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/23/13. Specifications subject to change without notice.
PAGE 1 OF 3
DPH-8-PAR-DIR
Gotham Architectural Downlighting
HID Downlights
8” DPH
PAR Directional
FE
AT
U
RE
S
OR
DER
ING
IN
FO
RM
AT
ION
OPTICAL SYSTEM
•
Center Beam optical system centers the lamp relative to the aperture, optimiz-
ing lamp efficiency.
•
Tool-less 0° - 40° vertical and 355° horizontal lamp adjustments made with the
trim assembly removed for simple focusing. Lockable adjustment mechanisms
maintain focus during relamping and are visible from below the ceiling with trim
assembly removed.
•
Designed to allow hot aiming.
•
Self-flanged, semi-specular or matte-diffuse cone designed to minimize
backflash. Contour cut reduces visibility of inner housing.
•
Trim assembly retained by self-aligning torsion support springs.
•
Internal housing components painted black.
MECHANICAL SYSTEM
•
Black painted housing features tool-less top access and accommodates a
maximum 1-1/2” ceiling thickness.
•
Re-lamp capability from above or below ceiling.
•
Mounting bars are 16-gauge galvanized steel with continuous 4” vertical adjust-
ment, held in place with tool-less, integral camaction locking. Post installation
adjustment possible without the use of tools from above or below the ceiling.
Shipped pre-installed.
•
Secondary housing adjustment system for precise, final ceiling to flange
alignment.
•
Galvanized steel junction box with bottom-hinged access covers and spring
latches. Two combination 1/2” - 3/4” and three 1/2” knockouts for straight-
through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated
for 90°C.
ELECTRICAL SYSTEM
•
Tool-less access door provides access to junction box through the aperture.
•
Medium base porcelain socket with nickel-plated screw shell.
•
Pre-wired, encased-and-potted, electromagnetic, 120/277V or 120/347V ballast
tray module is standard. Module can be attached before or after mounting of
mounting/plaster frame.
•
Thermally-activated insulation detector is replaceable without the use of tools.
LISTING
•
Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
•
1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
EXAMPLE: DPH P3039MHC 8ACT30 120 TRW
Series Lamp type
1
Wattage/Lamp
Aperture
Trim color
Type
Finish
Voltage
DPH
(blank)
P30
P38
Metal halide
70M
70W PAR38
100M
100W PAR38
Ceramic metal halide
39MHC
39W PAR30
70MHC
70W PAR38 or PAR30
100MHC
100W PAR38
150MHC
2
150W PAR38
8
AC
Clear
BC
3
Black
PC
Pewter
WTC
Wheat
GC
4
Gold
CC
4
Champagne gold
WC
3
White
MB
3
Contoured black baffle
WB
3
Contoured white baffle
T30
Cut for angles
25°-40°
T20
Cut for angles
15°-25°
T00
Cut for angles
0°-15°
(blank)
Semi-specular
LD
Matte-diffuse
LS
Specular
120
277
347
Ballast
Options
(blank) Electro-magnetic
ballast
HEB
5
Electronic
ballast
TRW
White painted flange (standard with WC, MB and WB)
RRL
6
RELOC
®
-ready luminaire. Provides compatibility with Lithonia RELOC
system. Access above ceiling required.
QRS
7
Quartz restrike system (uses 100W max. DC base quartz lamp by others)
QRSTD
7
Quartz restrike system with time delay
SF
Single fuse
EC
7
Emergency circuit (DC socket with leads for connection to
external emergency power source; 100W max. lamp)
CP
Chicago plenum
LPFL
Flood lamp (shipped separately)
LPSP
Spot lamp (shipped separately)
LPWFL
8
Wide flood lamp (shipped separately)
ACCESSORIES order as separate catalog numbers (shipped separately)
LFH702
Locking filter holder for all lamp types.
F500
9
Lens for use with 500 series filter holder
LTWFH500 DBL Filter holder for use with PAR30 lamps
F700
9
Lens for use with 700 series filter holder
LTWFH700 DBL Filter holder for use with PAR38 lamps