10” chl enclosed wet location cylinder – Gotham 10 CHL Enclosed Wet Location Cylinder SpecSheet User Manual
Page 3
![background image](/manuals/312792/3/background.png)
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/19/13. Specifications subject to change without notice.
PAGE 3 OF 3
CHL-10-LEnSEd
PH
OTO
M
ET
RY
10” CHL
Enclosed Wet Location Cylinder
Metal Halide, 8” Aperture
CHL10 100M 8RW FFL
MH100/C/U/MED LAMP, 1.0 S/MH, 8500 RATED LUMENS, TEST NO. LTL14369
CHL10 100M 8RW T73
MH100/C/U/MED LAMP, 1.0 S/MH, 8500 RATED LUMENS, TEST NO. LTL14368
CHL10 100M 8RW FFL
MH100/C/U/MED LAMP, 1.0 S/MH, 8500 RATED LUMENS, TEST NO. LTL14193
Distribution Curve
Distribution Data
Output Data
Coefficient of Utilization
Illuminance: Single Luminaire 30” Above Floor
0°
20°
40°
60°
80°
90°
180°
600
1200
1800
2400
3000
%
0
2
f
p
pc
80%
70%
50%
pw
50% 30% 10%
50% 30% 10%
50% 30% 10%
59
54
49
44
40
37
34
31
29
27
25
59
52
46
41
37
33
30
28
25
23
22
59
51
44
38
34
30
27
25
23
21
20
58
53
48
43
39
36
33
31
29
27
25
58
51
45
40
36
33
30
27
25
23
22
58
50
43
38
34
30
27
25
23
21
20
55
51
46
42
38
35
33
30
28
26
25
55
49
44
39
35
32
29
27
25
23
22
55
48
42
37
33
30
27
25
23
21
19
0
1
2
3
4
5
6
7
8
9
10
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
2038
2849
3887
4235
0
4235
24.0
33.5
45.7
49.8
0.0
49.8
Ave
Lumens
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90
3052
3006
2842
2113
1289
786
475
237
80
19
0
285
789
964
811
612
426
237
90
21
100.9
54.3
33.8
23.1
16.7
5.2
7.1
9.0
10.9
12.8
50.5
27.1
16.9
11.5
8.4
10.6
14.5
18.4
22.3
26.1
10.1
5.4
3.4
2.3
1.7
50% beam
50.9°
10% beam
88.1°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
0°
20°
40°
60°
80°
90°
180°
500
1000
1500
2000
2500
%
0
2
f
p
pc
80%
70%
50%
pw
50% 30% 10%
50% 30% 10%
50% 30% 10%
62
56
51
46
42
38
35
32
30
28
26
62
54
48
42
38
34
31
28
26
24
22
62
53
45
40
35
31
28
25
23
21
20
61
55
50
45
41
37
34
32
29
27
25
61
53
47
42
37
34
31
28
26
24
22
61
52
45
39
35
31
28
25
23
21
20
58
53
48
44
40
36
33
31
29
27
25
58
52
46
41
37
33
30
28
25
23
22
58
50
44
39
34
31
28
25
23
21
19
0
1
2
3
4
5
6
7
8
9
10
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1982
2919
4051
4444
0
4444
23.3
34.3
47.7
52.3
0.0
52.3
Ave
Lumens
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90
2797
2772
2609
2167
1501
896
480
256
98
23
0
262
731
988
938
696
436
255
110
27
92.5
49.7
31.0
21.1
15.3
5.7
7.8
9.9
12.0
14.0
46.2
24.9
15.5
10.6
7.7
11.4
15.6
19.8
23.9
28.1
9.2
5.0
3.1
2.1
1.5
50% beam
54.9°
10% beam
92.2°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
0°
20°
40°
60°
80°
90°
180°
700
1400
2100
2800
3500
%
0
2
f
p
pc
80%
70%
50%
pw
50% 30% 10%
50% 30% 10%
50% 30% 10%
65
58
52
47
43
39
36
33
31
28
27
65
57
50
44
39
35
32
29
27
25
23
65
55
47
41
36
32
29
26
24
22
20
63
57
51
47
42
39
35
33
30
28
26
63
55
49
43
39
35
32
29
26
24
23
63
54
46
41
36
32
29
26
24
22
20
60
55
50
45
41
38
35
32
30
28
26
60
54
47
42
38
34
31
28
26
24
22
60
52
45
40
35
32
28
26
24
22
20
0
1
2
3
4
5
6
7
8
9
10
Zone
Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
2896
4206
5934
6507
0
6507
24.1
35.0
49.4
54.2
0.0
54.2
Ave
Lumens
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90
3994
3969
3911
3125
2091
1315
787
387
135
32
0
380
1090
1426
1309
1021
707
388
149
36
132.0
71.0
44.3
30.2
21.9
5.7
7.8
9.9
12.0
14.0
66.0
35.5
22.1
15.1
11.0
11.6
15.8
20.0
24.3
28.5
13.2
7.1
4.4
3.0
2.2
50% beam
54.9°
10% beam
93.1°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.