beautypg.com

8” chu up/down, wall-mounted cylinder – Gotham 8 CHU Up_Down, Wall-Mounted Cylinder PAR SpecSheet User Manual

Page 4

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/31/13. Specifications subject to change without notice.

PAGE 4 OF 4

CHU-8-OPEn-PAR

PH

OTO
M

ET

RY

CHU8 P38100M 6AR

MP100PAR38/U/FL35/ECO LAMP, 0.6 S/MH, 5800 RATED LUMENS, TEST NO. LTL19287

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

8” CHU
Up/Down, Wall-Mounted Cylinder

PAR Metal Halide, 6” Aperture

20°

40°

60°

80°

100°

120°

140°

160°

180°

4600

9200

Ave

Lumens

0

5

15

25

35

45

55

65

75

85

90

11649

10525

7244

1877

157

16

3

1

1

0

0

953

1908

921

133

16

3

1

1

0

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

3781.9

3914.8

3933.3

3935.4

5.4

10.8

120.4

3509.8

7445.2

32.6

33.7

33.9

33.9

0.0

0.1

1.0

30.3

*64.2

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

69

63

58

54

50

47

44

41

39

37

35

69

61

55

50

46

43

40

37

35

33

32

69

60

53

48

44

40

37

35

33

31

29

64

59

54

50

47

44

42

39

37

35

34

64

57

52

48

44

41

38

36

34

32

31

64

56

50

45

42

39

36

34

32

30

29

55

51

47

45

42

40

38

36

34

33

31

55

50

46

43

40

37

35

33

32

30

29

55

49

44

41

38

35

33

31

30

28

27

RCR

50% beam -

32.3°

10% beam -

51.9°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

385.1

207.1

129.1

88.1

63.9

3.2

4.3

5.5

6.7

7.8

192.5

103.5

64.5

44.0

32.0

5.4

7.3

9.2

11.2

13.1

38.5

20.7

12.9

8.8

6.4

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.