beautypg.com

Conversion factor, Electrical characteristics – Gotham 11 LAH Square Lens DOL SpecSheet User Manual

Page 2

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2003-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/29/13. Specifications subject to change without notice.

PAGE 2 OF 3

LAH-11-SquARE-DOL

DIM

EN

SIO

N

AL D
AT

A

EL

EC

TR

IC

AL

11” LAH
Square Lens

Drop Opal Lens, Wet Location, Horizontal Lamp, Metal Halide or HPS Lamps

PH

OTO
M

ET

RY

All dimensions are inches (centimeters) unless otherwise noted.

13-1/4 (33.7)

23 (58.4)

Aperture:

10-1/8 (27.0)

Ceiling opening:

11-1/4 (28.6)

Overlap trim:

11-5/8 (29.5)

6 (15.2)

Conversion Factor

Use multiplier to determine

candlepower, lumens and

footcandles of other lamps.

50M = 100M x .35

50S = 100S x .43

70S = 100S x .68

QRS/EC WATTAGE RESTRICTIONS

HID

Maximum

Lamp

wattage

wattage

type

50W

75

Double contact

70/100W

100

bayonet base

Electrical Characteristics

Wattage/

Maximum Line Current

Input

V

8

0

2

V

0

2

1

t

s

a

ll

a

B

240V 277V 347V

watts

Metal Halide (Power Factor 90%)

50M HX-HPF

1.16

.67

.57

.50

.43

72

70M HX-HPF

1.90

1.04

.90

.80

.60

95

100M HX-HPF

2.60

1.50

1.30

1.15

1.00

130

High Pressure Sodium (Power Factor 90%)

50S HX-HPF

1.24

.59

.50

.44

66

70S HX-HPF

1.45

.85

.75

.65

.52

94

100S HX-HPF

2.20

1.40

1.10

.95

.70

130

Tested to current IES and NEMA standards under stabilized laboratory conditions. Various

operating factors can cause differences between laboratory data and actual field measure-

ments. Dimensions and specifications are based on the most current available data and are

subject to change.