beautypg.com

Gotham 8 CWU Up_Down, Wall-Mounted Cylinder SpecSheet User Manual

Page 3

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

PAGE 3 OF 3

CWU-8-OPEn

© 2007-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/31/13. Specifications subject to change without notice.

CWU8A MB

200W R40/FL LAMP, 0.9 S/MH, 2240 RATED LUMENS, TEST NO. LTL16071

CWU8A MB

300W R40/FL LAMP, 0.8 S/MH, 3650 RATED LUMENS, TEST NO. LTL16072

PH

OTO
M

ET

RY

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

8” CWU

Up/Down, Wall-Mounted Cylinder

PAR38, R40 Lamp

From 0°

cp. Lumens

1098

1081 103

15°

943

267

25°

675

313

35°

339

213

45°

85

66

55°

21

19

65°

2

2

75°

1

2

85°

1

1

90°

1

95°

2

3

105°

3

4

115°

7

7

125°

42

38

135° 131

101

145° 466

293

155° 776

359

165° 1032 292

175° 1178 112

180° 1198

Zone Lumens %lamp

0°-30° 683

15.2

0°-40° 896

20.0

0°-60° 981

21.9

0°-90° 966

22.0

90°-180° 1209

27.0

0°-180° 2195 49.0*

*Efficiency

ρ f

20%

ρc

80%

50%

30%

ρw 50% 30% 50% 30% 50% 30%

1 49 48 46 46 45 44

2 46 45 44 43 43 42

3 44 42 42 41 41 40

4 42 40 40 39 39 38

5 39 37 38 36 37 36

6 37 35 36 34 36 34

7 35 33 34 32 34 32

8 33 31 33 31 32 30

9 32 29 31 29 31 29

10 30 27 29 27 29 27

50%

10%

beam angle 65.6° beam angle 89.6°

Initial fc

fc at

fc at

Mount at beam

Beam beam

Beam beam

height center

diameter edge

diameter edge

8'

36.3

4.8' 18.1

9.2'

3.6

10'

19.5

6.5'

9.8

12.5'

2.0

12'

12.2

8.3'

6.1

15.9'

1.2

14'

8.3

10.0'

4.2

19.2'

0.8

16'

6.0

11.7'

3.0

22.6'

0.6

90°

135°

45°

180°

1200

960
720
480
240

240
480
720
960

1200

From 0°

cp. Lumens

1865

1837 174

15° 1560 441

25° 1071 496

35°

489

307

45°

194

150

55°

72

65

65°

16

16

75°

14

15

85°

12

13

90°

11

95°

12

13

105°

14

15

115°

16

16

125°

72

65

135° 194

150

145° 489

307

155° 1071 496

165° 1560 441

175° 1837 174

180° 1865

Zone Lumens %lamp

0°-30° 1111

15.2

0°-40° 1418

19.4

0°-60° 1633

22.4

0°-90° 1677

23.0

90°-180° 1677

23.0

0°-180° 3354 46.0*

*Efficiency

ρ f

20%

ρc

80%

50%

30%

ρw 50% 30% 50% 30% 50% 30%

1 45 43 35 35 30 29

2 41 38 33 31 28 27

3 37 35 30 29 26 25

4 34 32 28 27 25 23

5 31 29 26 24 23 22

6 29 26 25 23 22 20

7 27 24 23 21 20 19

8 25 22 22 20 19 18

9 24 21 20 18 18 17

10 22 19 19 17 17 16

50%

10%

beam angle 43.6° beam angle 78.2°

Initial fc

fc at

fc at

Mount at beam

Beam beam

Beam beam

height center

diameter edge

diameter edge

8'

61.7

4.4' 30.8

8.9'

6.2

10'

33.2

6.0' 16.6

12.2'

3.3

12'

20.7

7.6' 10.3

15.4'

2.1

14'

14.1

9.2'

7.1

18.7'

1.4

16'

10.2

10.8'

5.1

21.9'

1.0

90°

135°

45°

180°

2000
1600
1200

800
400

400
800

1200
1600
2000

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.