Gotham 8 AHW Open Wallwash SpecSheet User Manual
Page 3

© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/01/13. Specifications subject to change without notice.
PAGE 3 OF 3
AHW-8-OPEn
PH
OTO
M
ET
RY
8” AHW
Open Wallwash
Metal Halide Lamp
AHW 100MHC 8AR
(1) MPC100/C/U/MED lamp
8700 rated lumens
Test no. LTL7602
Vertical
Plane angle
angle
Room side
Wall side
Room 157½° 135° 112½° 90°
67½° 45° 22½° Wall
0°
9232 9232 9232 9232 9232
9232 9232 9232 9232
5°
9264 8931 8442 7964 7527
7254 7055 6949 6826
15° 6058 5896 5612 5284 5234
5114 5084 4991 4761
25° 3800 3668 3625 3428 3210
3041 2988 2818 2609
35° 2169 2046 1965 1845 1776
1621 1707 1603 1506
45°
456 449 458 431 478
560 850 818 769
55°
12
12
14
12
14
163 474 462 447
65°
12
0
2
5
8
106 311 276 252
75°
0
0
5
5
8
59 142 100 94
85°
12
2
2
0
0
30
20
5
5
90°
0
0
0
0
0
0
0
0
0
Luminaire 3' from wall
Luminaire 3' from wall
on 3' centers
on 4' centers
1
27 25 27
19 19 19
2
57 54 57
41 41 41
3
64 63 64
47 46 47
4
70 69 70
50 54 50
5
71 71 71
53 55 53
6
68 70 68
51 53 51
7
64 65 64
48 50 48
8
60 61 60
45 47 45
9
55 57 55
43 43 43
10
50 52 50
39 40 39
AHW 100MHC 8AR CGL
(1) MPC100/C/U/MED lamp
8700 rated lumens
Test no. LTL7864
Vertical
Plane angle
angle
Room side
Wall side
Room 157½° 135° 112½° 90°
67½° 45° 22½° Wall
0°
8493 8493 8493 8493 8493
8493 8493 8493 8493
5°
8523 8217 7767 7327 6925
6674 6491 6393 6280
15° 5573 5424 5163 4861 4815
4705 4677 4592 4380
25° 3496 3375 3335 3154 2953
2798 2749 2593 2400
35° 1995 1882 1808 1697 1634
1491 1570 1475 1386
45°
420 413 421 397 440
515 782 753 707
55°
11
11
13
11
13
150 436 425 411
65°
11
0
2
5
7
98 286 254 232
75°
0
0
5
5
7
54 131 92
86
85°
11
2
2
0
0
28
18
5
5
90°
0
0
0
0
0
0
0
0
0
Luminaire 3' from wall
Luminaire 3' from wall
on 3' centers
on 4' centers
1
25 23 25
18 18 18
2
52 50 52
38 37 38
3
59 58 59
44 43 44
4
64 64 64
46 49 46
5
65 65 65
49 50 49
6
63 64 63
47 49 47
7
59 59 59
44 46 44
8
55 56 55
41 43 41
9
50 52 50
39 40 39
10
46 48 46
36 37 36
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
room
wall
90
0
112
0
1 2
135
0
157
0
1 2
67
0
1 2
45
0
22
0
1 2
Fixture/Lamp
Candlepower Data
Footcandle values
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.