4” ahw open wallwash – Gotham 4 AHW Open Wallwash SpecSheet User Manual
Page 3
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/01/13. Specifications subject to change without notice.
PAGE 3 OF 3
AHW-4-OPEn
PH
OTO
M
ET
RY
4” AHW
Open Wallwash
Metal Halide Lamp
AHW 70M 4AR
70W ED-17 lamp
4700 rated lumens
Test no. LTL13275
P lane Angle
R oom S ide W all S ide
Vertical Angle
R oom 157.5°
135° 112.5° 90° 67.5° 45° 22.5° W all
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
1146
1159
1217
1049
759
337
24
5
3
1
0
1146
1159
1181
1012
743
363
38
5
3
1
0
1146
1161
1127
936
699
350
42
6
3
1
0
1146
1132
1035
835
598
328
43
6
3
1
0
1146
1133
1001
853
605
320
53
7
3
1
0
1146
1131
966
875
644
361
94
28
8
2
0
1146
1090
928
868
664
388
148
68
18
2
0
1146
1064
908
862
673
405
201
91
24
3
0
1146
1061
906
876
695
447
217
97
25
3
0
3 ft. from wall
3 ft. from wall
on 3 ft. centers
on 4 ft. centers
1
2
3
4
5
6
7
8
9
10
5
17
25
27
25
22
18
15
12
10
4
16
24
28
25
21
18
15
12
10
5
17
25
27
25
22
18
15
12
10
5
14
20
20
19
16
13
11
9
8
3
10
16
21
19
16
14
11
9
8
5
14
20
20
19
16
13
11
9
8
Luminaire
Luminaire
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
room
wall
90
0
112
0
1 2
135
0
157
0
1 2
67
0
1 2
45
0
22
0
1 2
Fixture/Lamp
Candlepower Data
Footcandle values
PHOTOMETRY NOTES
•
Tested to current IES and NEMA standards under stabilized laboratory conditions.
•
Actual performance may differ as a result of end-user environment and application.
•
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.