beautypg.com

8” evo non-conductive shower light, retrofit kit – Gotham 8 Evo Non-Conductive Shower Light SpecSheet User Manual

Page 3

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2011-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/12/13. Specifications subject to change without notice.

PAGE 3 OF 3

EVO-R-8-SHOWER

PH

OTO
M

ET

RY

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

8” EVO

Non-Conductive Shower Light, Retrofit Kit

Solid-State Lighting

EVO-R 35/18 8DFR

INPUT WATTS: 34, DELIVERED LUMENS: 1182, LM/W=34.8, 1.0 S/MH, TEST NO. LTL20134

PHOTOMETRY NOTES

Tested in accordance with IESNA LM-79-08.

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Actual wattage may differ by +/- 10% when operating between 120-277V +/- 10%.

CRI: 83 typical.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.

EVO-R 35/22 8DFD

INPUT WATTS: 44, DELIVERED LUMENS: 1568, LM/W=35.6, 1.0 S/MH, TEST NO. LTL20136

EVO-R 35/22 8DFR

INPUT WATTS: 44, DELIVERED LUMENS: 1547, LM/W=35.2, 1.0 S/MH, TEST NO. LTL20137

20°

40°

60°

80°

200

400

600

800

Ave Lumens

0

5

15

25

35

45

55

65

75

85

90

874

883

873

697

408

185

69

34

22

11

5

85

244

316

255

145

65

34

23

12

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

644.4

899.6

1110.1

1179.0

3.3

3.3

3.3

3.3

1182.4

54.5

76.1

93.9

99.7

0.3

0.3

0.3

0.3

*100.0

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

119

108

99

91

83

77

71

66

62

58

54

119

105

94

84

77

70

64

59

55

51

47

119

103

90

80

72

65

59

54

50

46

43

116

106

97

89

82

76

70

65

61

57

53

116

103

93

83

76

69

64

59

54

51

47

116

101

89

79

71

64

59

54

50

46

43

111

102

94

86

80

74

69

64

60

56

53

111

100

90

82

74

68

63

58

54

50

47

111

98

87

78

70

64

58

54

50

46

43

RCR

50% beam -

55.1°

10% beam -

85.9°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

28.9

15.5

9.7

6.6

4.8

5.7

7.8

9.9

12.0

14.1

14.4

7.8

4.8

3.3

2.4

10.2

14.0

17.7

21.4

25.1

2.9

1.6

1.0

0.7

0.5

20°

40°

60°

80°

400

800

Ave

Lumens

0

5

15

25

35

45

55

65

75

85

90

1168

1171

1110

904

548

259

97

47

30

15

8

111

311

410

343

202

91

48

32

16

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

832.5

1175.0

1468.6

1564.2

4.6

4.6

4.6

4.6

1568.8

53.1

74.9

93.6

99.7

0.3

0.3

0.3

0.3

*100.0

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

119

108

99

90

83

76

71

65

61

57

53

119

105

94

84

76

69

63

58

54

50

47

119

102

89

79

71

64

58

53

49

46

42

116

106

97

89

82

75

70

65

60

56

53

116

103

92

83

75

69

63

58

54

50

46

116

101

88

79

70

64

58

53

49

45

42

111

102

93

86

79

73

68

63

59

55

52

111

100

90

81

74

68

62

57

53

49

46

111

97

86

77

70

63

58

53

49

45

42

RCR

50% beam -

54.5°

10% beam -

86.4°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

38.6

20.8

12.9

8.8

6.4

5.7

7.7

9.8

11.9

13.9

19.3

10.4

6.5

4.4

3.2

10.3

14.1

17.9

21.6

25.4

3.9

2.1

1.3

0.9

0.6

20°

40°

60°

80°

400

800

1200

Ave

Lumens

0

5

15

25

35

45

55

65

75

85

90

1325

1319

1251

996

556

204

65

30

14

2

0

125

350

451

347

164

62

31

15

3

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

925.6

1272.3

1498.2

1547.1

0.0

1547.1

59.8

82.2

96.8

100.0

0.0

*100.0

*Efficiency

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

0

1

2

3

4

5

6

7

8

9

10

119

110

101

93

86

79

74

69

64

60

57

119

107

96

87

80

73

67

62

58

54

50

119

104

92

83

75

68

62

58

53

50

46

116

107

99

91

85

78

73

68

64

60

56

116

105

95

86

79

72

67

62

58

54

50

116

103

91

82

74

68

62

57

53

49

46

111

103

96

89

82

77

71

67

63

59

55

111

101

92

84

77

71

66

61

57

53

50

111

99

89

81

73

67

62

57

53

49

46

RCR

50% beam -

53.4°

10% beam -

82.6°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

43.8

23.6

14.7

10.0

7.3

5.5

7.5

9.5

11.6

13.6

21.9

11.8

7.3

5.0

3.6

9.7

13.2

16.7

20.2

23.7

4.4

2.4

1.5

1.0

0.7