Remote contr ol, cont’d – Extron Electronics MAV Plus series Large Scale Setup Guide User Manual
Page 17

Cr
ossPoint / MA
V Matrix Switchers • Remote Contr
ol
Remote Contr
ol, cont’d
4-8
Cr
ossPoint / MA
V Matrix Switchers • Remote Contr
ol
4-9
Refer also to the
Cr
ossPoint 450 Plus / MA
V Plus User’
s Manual
at
www
.extron.com
.
Refer also to the
Cr
ossPoint 450 Plus / MA
V Plus User’
s Manual
at
www
.extron.com
.
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Information requests
Information request
I
V
X*
X
X(
•A
X*
X
X(
T
X1@
U
X1#]
V
X*
X
X(
= video size, A
X*
X
X(
= audio size,
T
X1@
= BME type, U
X1#
= # of BMEs in system.
Example:
MAV 450 Plus 6448 with a
connected audio BME
I
V64X48•A64X48•T2•U2
]
This low resolution matrix switcher (T2) has 64 video
and 64 audio inputs by 48 video and 48 audio inputs.
This is a two BME system (a video and audio BME).
Request part number
N
X1)]
Query controller firmware version
Q
X1!]
Example:
Q
1.23
]
The factory-installed controller firmware version is
1.23 (sample value only).
N
X1$
= Name
(Up to 240 alphanumeric characters)
X1%
= IP address
###.###.###.###
X1^
= DHCP
0 = off
1 = on
X1&
= Verbose mode 0 = clear/none (default for Telnet connection) 2 = tagged responses for queries
1 = verbose mode (RS-232/RS-422 default)
3 = verbose mode and tagged for queries
X1*
= Port timeout
1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
IP setup
Set matrix name
EX1$
CN
}
Ipn•
X1$]
Read matrix name
E
CN
}
X1$]
Reset matrix name to factory default
E
•CN
}
Ipn•
X1$]
Model name plus the last 3 pairs of the MAC address.
Set IP address
EX1%
CI
}
Ipi
X1%]
Read IP address
E
CI
}
X1%]
Set subnet mask
EX1%
CS
}
Ips
X1%]
Read subnet mask
E
CS
}
X1%]
Set gateway IP address
EX1%
CG
}
Ipg
X1%]
Read gateway IP address
E
CG
}
X1%]
Set DHCP on or off
EX1^
DH
}
Idh
X1^]
Read DHCP on/off status
E
DH
}
X1^]
Set verbose mode
EX1&
CV
}
Vrb
X1&]
Read verbose mode
E
CV
}
X1&]
Configure current port timeout
E
0*
X1*
TC
}
Pti0*
X1*]
Read current port timeout
E
0TC
}
X1*]
Configure global IP port timeout
E
1*
X1*
TC
}
Pti1*
X1*]
Read global IP port timeout
E
1TC
}
X1*]
N
X*
= Inputs
Total number of inputs for this switcher
X(
= Outputs
Total number of outputs for this switcher
X1)
= Part number
See the CrossPoint 450 Plus / MAV Plus User’s Manual, for a complete list of part numbers.
X1!
= Firmware version number to second decimal place (x.xx)
X1@
= BME type
1 = wideband video
3 = sync
5 = mono audio
2 = low resolution video
4 = stereo audio
X1#
= # of connected BMEs
1 through 6