Connect the switcher to the display device, Connect the display to the system controller, Connect the system controller to the switcher – Extron Electronics TeamWork Kits Installation User Manual
Page 10: Connect power, Converter sis commands, Teamwork kits • installation guide (continued), Converter sis, Commands
TeamWork Kits • Installation Guide (Continued)
10
Connect the Switcher to the Display Device
Connect the switcher HDMI output to the HDMI input of the display device, using the provided cable. Do not use HDMI to DVI
adapters. If necessary, see the user guide for the display device.
Connect the Display to the System Controller
Connect the power cord from the display device to the power output receptacle of the system controller. TeamWork systems work
by controlling the AC power to the display.
ATTENTION:
If you are using the IPL T PC1i (International TeamWork kits) you must replace the power plug on the display
with the provided adapter. (For instructions, see page 3.)
Connect the System Controller to the Switcher
Connect the COM port of the system controller to the RS-232 port on the switcher with the provided control cable.
System Controller
(IPL T PC1)
COM
TX
+5V
RX
Switcher
(SW4 HDMI)
Tx Rx
RS-232 AUTO
5-pole connector
(to switcher)
4-pole connector
(to system controller)
Switcher Control Cable
ATTENTION:
The two ends of the RS-232 control cable are different. One has a 4 pole connector, the other has a 5 pole
connector.
Connect Power
The system controller uses an internal power supply. Connect the power cord to a wall outlet.
The TeamWork 600 systems use a 6 input switcher with an internal power supply. Connect the power cord to a wall
outlet.
The TeamWork 400 systems use a 4 input switcher with a 12 VDC, 1 A power supply, which is provided with the
switcher.
ATTENTION:
Do not connect the power supply to the SW4 HDMI switcher until you have read the Attention
notifications in the “Wiring the Power Supply” section of the SW HDMI Series User Guide.
The optional TeamWork VGA kit also includes a 12 VDC, 1 A power supply for the analog to digital converter.
Converter SIS
™
Commands
The following features have been pre-configured on the RGB-HDMI 300 A. The values should be re-entered if they have been
erased by a factory reset (see the RGB-DVI 300 and RGB-HDMI 300 (A) User Guide at
explanation of SIS commands).
Feature
SIS Command
Set output signal resolution to 1080p
E
24*8RATE
}
Enable power save mode
E
1PSAV
}
Enable Auto-Image
1*1A
Disable auto memories
E
0AMEM
}
Enable front panel security lockout
1X
0.4A MAX
POWER
12V
E
= Escape key
}