Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual
Page 9

5-9
MLC 104 Series • SIS
™
Programming and Control
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued)
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)
V
olume adjustment (discr
ete, for volume mode = 0)
Set the overall output volume
14
X8
V
X8
V
V
ol
X8
Specify the volume for audio output.
14
= The MLC responds with an E14 err
o
r
code (invalid) if the MLC is in volume
increment/decrement mode (vol. mode 1).
X8
= volume level (0 to 100). Default = 40 if
no switcher is connected, 100 if an MLS
switcher is connected. The maximum level
is limited by the X*47# command.
Example
:
27V
27V
V
o
l027
Example
: set volume to 27.
Incr
ement the volume
+
V
%2BV
V
o
l
X8
Incr
ease audio output.
Decr
ement the volume
-V
%2DV
V
o
l
X8
Decrease audio output.
V
iew the volume level
V
V
X8
Show the output volume.
V
o
lume adjustment (incr
ement/decr
ement, for volume mode = 1)
Incr
ement the volume
+
V
%2BV
V
ol+
Incr
ease audio output.
Decr
ement the volume
-V
%2DV
V
ol-
Decrease audio output.
V
iew the volume level
V
V
--
-
Show the output volume.
Audio mute
Mute on
1Z
1Z
Amt1
Mute all audio outputs. This is
not
the same
as selecting input 0.
Mute of
f
0Z
0Z
Amt0
Unmute all audio outputs.
V
iew the audio mute status
Z
Z
X5
Show the status of audio mute.
X5
= 0 (off) or 1 (on).
F
ront panel security lockout modes (executive modes)
Disable lockout modes
24
0X
0X
Exe 0
Default setting. Adjustments & selections
can be made from the fr
ont panel in
addition to via RS-232, T
elnet, or W
eb
b
rowser
.
24
= The MLC responds with an E24 err
o
r
(privilege violation) if the connected user is
not logged in at administrator security level.