Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual
Page 15

5-15
MLC 104 Series • SIS
™
Programming and Control
PRELIMINAR
Y
Ethernet data port configuration and use
Set global IP port timeout period
24
Esc
1*
X6
9
TC
W1%2A
X6
9
TC
|
Pti 1*
X6
9
The global port timeout is the default
timeout period for all T
elnet sessions.
X6
9
=
IP connection timeout period in seconds.
Each step is specified in 10-second intervals
(1 - 65000, default = 30 = 300 seconds). If no
data is r
eceived during the specified period,
the Ethernet connection will be closed.
Responses are
r
eturned with leading zeros.
This variable is applicable only when the
MLC is connected via Ethernet, and you
must be logged in as an administrator to
change this setting.
V
iew global IP port timeout period
Esc
1TC
W1TC
|
X6
9
Set curr
ent port’s timeout period
24
Esc
0*
X6
9
TC
W0
%
2A
X6
9
TC
|
Pti 0*
X6
9
The current port timeout period applies to
the currently open T
elnet session only
.
When you start another T
elnet session, it
uses the default global port timeout period.
X6
9
= timeout period in seconds. See the
description above.
This variable is applicable only when the
MLC is connected via Ethernet. If the MLC
is connected via RS-232 protocol, only the
global timeout commands apply
, and any
commands involving
X6
9
r
eturn the E13
error response.
V
iew curr
ent port’s timeout period
Esc
0TC
W0TC
|
X6
9
Command/r
esponse table for SIS commands (continued)
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)