Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual
Page 11
5-11
MLC 104 Series • SIS
™
Programming and Control
PRELIMINAR
Y
V
iew power sensor status
8S
8S
X213
If the switcher is connected to an Extro
n
Power Sensor that monitors the projector/
display
, this tells you whether the display is
still powered on.
X213
is as follows:
00 = power sensor is connected and is not
sensing projector power (detector voltage is
low
, signal pin voltage is high).
01 = power sensor is connected and sensing
p
rojector power (detector voltage is high).
02 = sensor is disconnected or sensor is
connected but sensitivity is too high (voltage
is low at both the detector and signal pin).
V
iew power sensor signal pin status
9S
9S
X214
Power sensor signal pin status:
00 = voltage is low
.
01 = voltage is high.
V
iew all voltage & temp.
status
11
S
11S
responses fr
om commands 12S
•
14S
•16S•20S
V
iew all voltages and the MLC’s internal
temperature at once.
V
iew +12 V power supply voltage
12S
12S
+
X206
Display the operating voltage of the MLC’s
power input.
X206
= voltage.
V
iew +3.3 V IP
Link/FPGA
voltage
14S
14S
+
X206
V
iew -10 V IR/Serial bus voltage
16S
16S
-
X206
Display the operating voltage for the IR/
Serial and pr
ojector ports.
V
iew internal temperature status
20S
20S
X207
Display the internal operating temperature
.
X207
= temperature in degr
ees Celsius (the
response is 3 digits including leading zer
os).
Command/r
esponse table for SIS commands (continued)
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)