beautypg.com

Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual

Page 11

background image

5-11

MLC 104 Series • SIS

Programming and Control

PRELIMINAR

Y

V

iew power sensor status

8S

8S

X213

If the switcher is connected to an Extro

n

Power Sensor that monitors the projector/

display

, this tells you whether the display is

still powered on.

X213

is as follows:

00 = power sensor is connected and is not

sensing projector power (detector voltage is

low

, signal pin voltage is high).

01 = power sensor is connected and sensing

p

rojector power (detector voltage is high).

02 = sensor is disconnected or sensor is

connected but sensitivity is too high (voltage

is low at both the detector and signal pin).

V

iew power sensor signal pin status

9S

9S

X214

Power sensor signal pin status:

00 = voltage is low

.

01 = voltage is high.

V

iew all voltage & temp.

status

11

S

11S

responses fr

om commands 12S

14S

•16S•20S

V

iew all voltages and the MLC’s internal

temperature at once.

V

iew +12 V power supply voltage

12S

12S

+

X206

Display the operating voltage of the MLC’s

power input.

X206

= voltage.

V

iew +3.3 V IP

Link/FPGA

voltage

14S

14S

+

X206

V

iew -10 V IR/Serial bus voltage

16S

16S

-

X206

Display the operating voltage for the IR/

Serial and pr

ojector ports.

V

iew internal temperature status

20S

20S

X207

Display the internal operating temperature

.

X207

= temperature in degr

ees Celsius (the

response is 3 digits including leading zer

os).

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)