Preliminar y, Programming and control, cont’d – Extron Electronics MLC 104 SIS Programming and Control User Manual
Page 18

SIS
™
Programming and Control, cont’d
MLC 104 Series • SIS
™
Programming and Control
5-18
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued)
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)
Examples:
32
I
32
I
P101 P200 K100 K200 K300 K400 S00
This example includes one
SCP (P101) and
no slaved switcher
.
32
I
32
I
P100 P201 K100 K200 K300 K400 S09
This example includes one
SCP (P201) and
an MLS 102 VGA (S09).
IP setup commands
Set the unit name
24
Esc
X1
2
CN
W
X1
2
CN
|
Ipn•
X1
2
Change the MLC’s name to one of your
choosing (
X1
2
), such as “AuditoriumMLC”,
“Rm316-A
Vcenter”, or “exec-boar
d
room-
ctrl”. The name consists of up to 24
alphanumeric characters (and the minus
sign). The first character must be a letter
,
the last character cannot be a minus sign
(hyphen). Case does not matter
.
Set unit name to factory default
24
Esc
•CN
W%20CN
|
Ipn•
X4
9
X4
9
= the name the MLC was shipped with:
MLC-104-IP-##-##-## or MLC-104-##-##-##,
a combination of the model name and the
last 3 pairs of hex numbers in the
controller
’s MAC address (e.g., MLC-104-IP-
00-02-3D).
Read the unit name
Esc
CN
WCN
|
X1
2
or
X4
9
X1
2
is the MLC’s curr
ent, user-defined unit
name.
X4
9
is the MLC’s factory default name.
Set time/date
24
Esc
X1
3
CT
W
X1
3
CT
|
Ipt•
X1
3
X1
3
= Local date and time format.
The
set
format is
MM/DD/YY
-HH:MM:SS
.
Example: 03/08/05-10:54:00
.
Read time/date
Esc
CT
WCT
|
X1
3
X1
3
= Local date and time format.
The
Read
format is
day of week, DD month
year HH:MM:SS
.
Example: T
ue, 08 Mar 2005 18:19:33.