Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual
Page 17

5-17
MLC 104 Series • SIS
™
Programming and Control
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued)
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)
Query updated firmwar
e version
4Q
4Q
X1
1
(kernel version–model description–date time of upload)
Use this command to find out which version
of the firmware, if any was uploaded into
the controller after it left the factory
.
Example:
4Q
4Q
1.00*(1.18-MLC104 -Thu, 15 Sep 2005 22:42:14
GMT)
In this example the current firmware version
is 1.00, the IP Link kernel version is
1.18, for
the MLC 104, dated 15 September
, 2005.
In a query response, an asterisk (
*) after the version number indicates the version that is curr
ently used.
A
question mark (
? or
?.??
) indicates that the factory default firmwar
e is the only firmware loaded in the switcher
.
A
carat (
^
) indicates the version of firmware that should be running, but, since a mode 1 reset was performed, the factory default firmwa
re
version is loaded and running instead.
An exclamation point (
!) indicates that the firmware is corrupted.
Query FPGA version
3
2Q
32
Q
X1
1
Show the field-programmable gate array
(FPGA) firmware version to two decimal
places (x.xx).
Request the MLC’s part number
N
N
60-xxx-00
Show the MLC’s part #. 60-573-00 =
MLC 104 IP
, 60-665-00 = MLC 104.
Request
A/V input number
I
I
Chn
X200
Show which input is active (selected).
X200
is the input number
.
Request the model name
1I
1I
MLC 104 IP
or MLC 104
Request the model description
2I
2I
MLC 104 w/ IP
MLC 104 with IP contr
ol.
Request system memory usage
3I
3I
# bytes used out of # of kbytes
Show amount of memory used and total
available memory for system operations.
Request user memory usage
4I
4I
# bytes used out of # of kbytes
Show amount of user memory used and
total available user memory
.
Example:
4I
4I
217856 Bytes Used out of 7232 KBytes
Request status of attached har
dware
32
I
32
I
P1##•P2##•K1##•K2##•K3##•K4##•S
Show the absence of or types of connected
devices.
For ##:
00 =
n
o
t pr
ese
nt
* 00
is
the val
u
e (##) for K1, K2, K3, a
n
d K4 for
the MLC 104
S
er
ies beca
u
se
they do
n
o
t s
u
ppor
t
co
nt
ro
l mod
u
les (IRCMs, ACMs, CCs, RCMs)
For :
00 =
n
o
t pr
ese
nt
01 = ML
S
306
02 = ML
S
506
03 = ML
S
506 MA
70 V
04 = ML
S
506
S
A
05 = ML
S
506 MA
100 V
06 = ML
S
100 A
07 = ML
S
103 V
Prefixe
s for connected device
s:
P1 =
S
CP
#1, addr
ess 0
P2 =
S
CP
#2, addr
ess 1
K1 =
co
nt
rol mod
u
le #1, addr
ess 0
*
K2 =
co
nt
rol mod
u
le #2, addr
ess 1
*
K3 =
co
nt
rol mod
u
le #3, addr
ess 2
*
K4 =
co
nt
rol mod
u
le #4, addr
ess 3
*
S
=
Med
iaL
in
k dev
ice,
typ
ically
a slaved ML
S
sw
it
cher
.
08 = ML
S
103
S
V
09
= ML
S
102 VGA
10 = MLA-VC10
11
=
M
L
S
304 MA
12 = ML
S
406
13 = ML
S
406 MA
14 = ML
S
406
S
A
15 = ML
S
304
S
A