Extron Electronics IN3526vi User Manual
Page 12
8
IN3526VI OPERATION MANUAL - REV. 2 12/01/98 ©1997 - INLINE, INC.
RS-232 COMMAND PROTOCOL
Command*
Function
Response*
ACI3
Set baud rate to 1200, default setting
OK
ACI4
Set baud rate to 2400
OK
ACI5
Set baud rate to 4800
OK
ACI6
Set baud rate to 9600
OK
ACI7
Set baud rate to 19200
OK
BLANK0
Blank output (no input selected)
OK or CH1
BLANK1
Un-blank output (selects previous input)
OK or CH1
CH0
Blank output (same as pressing the front panel BLANK button)
OK or CH1
CH1
Select Input 1
OK or CH1
CH2
Select Input 2
OK or CH1
CH3
Select Input 3
OK or CH1
CH4
Select Input 4
OK or CH1
CH5
Select Input 5
OK or CH1
CH6
Select Input 6
OK or CH1
CMDCD0
Select "[" & "]"
OK
CMDCD1
Select "{" & "}"
OK
CMDCD2
Select "(" & ")"
OK
CMDCD3
Select "<" & ">"
OK
SCAN0
Disable scan mode
OK
SCAN1
Enable scan mode
OK
SCANx
Configure scan to scan up to channel x where x = 2 to 6.
OK
SCANTx
Set scan time as follows:
x = 1: 2.5 seconds
x = 2: 5 seconds
x = 3: 7.5 seconds
x = 4: 10 seconds
x = 5: 15 seconds
x = 6: 20 seconds
x = 7: 30 seconds
OK
FP
Enable/Disable the front panel (toggle)
OK
FP0
Disable the front panel
OK
FP1
Enable the front panel
OK
INF0
Get the firmware version
IN3526VI V1.0
INF1
Get the currently selected input
0 to 6 (0 is for Blank)
* Command codes are not shown for clarification purposes.
RS-232 SAMPLE COMMANDS
Description
Command
Response
Switch to Input 2 (for a Slave switcher)
[CH2]
[OK]
Switch to Input 2 (for a Master switcher)
[CH2]
[CH1]
Get status of input selected
[INF1]
[2]
Disable Front Panel operation
[FP0]
[OK]
Change baud rate to 4800
[ACI5]
[OK]
Change command codes to { }
[CMDCD1]
{OK}