Front panel config port, Remote rs232/rs422 connector – Extron Electronics DXP DVI Pro Setup Guide User Manual
Page 16

10
DXP DVI Pro and DXP HDMI Series • Setup
g
Remote RS232/RS422 connector — Connect an RS-232 capable
host device such as a computer or a touch panel control to the
switcher via this 9-pin D connector for serial RS-232 or RS-422
control.
RS-232 Function
Pin
Function
1
2
3
4
5
6
7
8
9
—
Tx
Rx
—
Gnd
—
—
—
—
Not used
Transmit data
Receive data
Not used
Signal ground
Not used
Not used
Not used
Not used
—
Tx–
Rx–
—
Gnd
—
Rx+
Tx+
—
Not used
Transmit data (–)
Receive data (–)
Not used
Signal ground
Not used
Receive data (+)
Transmit data (+)
Not used
RS-422
5
1
9
6
RS232/RS422
REMO
TE
Figure 7.
Remote RS232/RS422 Connector
In the "Remote Control" section, see “
” for
definitions of some of the SIS commands (serial commands to
control the switcher via this connector) and "
Starting the Matrix Switchers Control Program
how to install and use the control software.
Front Panel Config Port
If desired, connect a control system or computer to the front panel
RS-232 Config port. Protocol for the port is:
•
9600 baud
•
8 data bits
•
1 stop bit
•
No parity
•
No flow control
AUDIO
VIDEO
I/O
CONTROL
ENTER
PRESET
VIEW
ESC
CONFIG
DIGITAL MATRIX SWITCHER
DXP SERIES
RS-232
Configuration Port
Figure 8.