beautypg.com

Extron Electronics CTL101 User Manual

Page 23

background image

19

©2002 - INLINE, Inc.

CTL101 Operation Manual - V1.3 03/22/02

2 & 3. Set / Change / Clear / Display a Code - will prompt users to push an IR remote control
button to be associated with the operations. Another prompt will be displayed to verify the
selection. If the IR signal is acceptable, the unit will indicate if it is a "New" or "Existing"
command code.

A new feature includes Hexadecimal code entry (HEX format). HEX format codes must be
entered in pairs (even number of entries). Also, in ASCII format, Carriage Return (Ctrl M) and
Line Feed (Ctrl J) may now be entered as part of the code string (they were previously ignored).
HEX format code entry must be in capital letters "0-F" (Version 1.01 or later in self test).

Select one of the following:

1. Enter Code - If selected, two menus will be displayed:

First Menu:

Enter Selection.
1. Remote Delay ON - for Single push
2. Remote Delay OFF - for Continuous push

Users are now prompted to program the CTL101 for either single push operation (which
repeats the code no faster than 2 times per second), or for continuous operation (to repeat
the code 20 times per second while the button is pushed). Single push modes are utilized
for most operations, while continuous push modes are primarily used for such functions as
volume regulation.

Second Menu:

Begin entering Command codes

- End with a Code End character (Default = asterisk *)

- Backspaces will be ignored.


After the remote has been configured, the unit will automatically begin the code entry mode
(which is the same as contact closure entry). The group has the capacity to store up to 72
individual remote command strings.

2. Delete Code - deletes the previously programmed command.

3. Display Current - shows the current command status.

4. Select Current Code Group - allows users to enable one of the three groups.